Command | Default Data Type | Description | Part | Axis | R/W | Data Range |
M_SSEC_CCLK_BASE_EXCHG_NO1 | T_CHAR | 1st slot Station No. | -- | -- | RW | -1 to 64 |
M_SSEC_CCLK_BASE_TRANS_SP1 | T_CHAR | 1st slot Transmission rate and mode | -- | -- | RW | 0 to 14 |
M_SSEC_CCLK_BASE_ABNML_LINK1 | T_CHAR | 1st slot Setting of data link faulty station | -- | -- | RW | 0,1 |
M_SSEC_CCLK_BASE_PLC_STOP1 | T_CHAR | 1st slot Setting at PLC STOP | -- | -- | RW | 0,1 |
M_SSEC_CCLK_BASE_OCCUP_BUREAUX1 | T_CHAR | 1st slot Number of occupied stations | -- | -- | RW | 0 to 4 |
M_SSEC_CCLK_BASE_CYCLIC1 | T_CHAR | 1st slot Extended cyclic setting | -- | -- | RW | 0,1,2,4,8 |
M_SSEC_CCLK_BASE_CONNECT_NUM1 | T_CHAR | 1st slot Number of connected modules | -- | -- | RW | 0 to 64 |
M_SSEC_CCLK_BASE_RETRY1 | T_CHAR | 1st slot Number of retries | -- | -- | RW | 0 to 7 |
M_SSEC_CCLK_BASE_AUTO_OPE_MATA1 | T_CHAR | 1st slot Number of automatic return modules | -- | -- | RW | 0 to 10 |
M_SSEC_CCLK_BASE_STANDBY_MASTER1 | T_CHAR | 1st slot Standby master station | -- | -- | RW | 0 to 64 |
M_SSEC_CCLK_BASE_NC_DOWN1 | T_CHAR | 1st slot Operation at NC down | -- | -- | RW | 0,1 |
M_SSEC_CCLK_BASE_SCAN_MODE1 | T_CHAR | 1st slot Scan mode | -- | -- | RW | 0,1 |
M_SSEC_CCLK_BASE_DELAY_TIME1 | T_CHAR | 1st slot Delay time | -- | -- | RW | Fixed to 0 |
M_SSEC_CCLK_BASE_RX_DEV1 | T_CHAR | 1st slot Remote input (RX) refresh device name | -- | -- | RW | X,M,L,B,D,W,R |
M_SSEC_CCLK_BASE_RX_NO1 | T_SHORT | 1st slot Remote input (RX) refresh device No. | -- | -- | RW | Depends on the device name X0 to X5FF M0 to M10239 L0 to L511 B0 to B1FFF D0 to D2047 W0 to W1FFF R8300 to R9799 R9800 to R9899 |
M_SSEC_CCLK_BASE_RY_DEV1 | T_CHAR | 1st slot Remote output (RY) refresh device name | -- | -- | RW | Y,M,L,B,D,W,R |
M_SSEC_CCLK_BASE_RY_NO1 | T_SHORT | 1st slot Remote output (RY) refresh device No. | -- | -- | RW | Depends on the device name Y0 to Y5FF Others are the same with RX |
M_SSEC_CCLK_BASE_RWR_DEV1 | T_CHAR | 1st slot Remote register (RWr) refresh device name | -- | -- | RW | M,L,B,D,W,R |
M_SSEC_CCLK_BASE_RWR_NO1 | T_SHORT | 1st slot Remote register (RWr) refresh device No. | -- | -- | RW | Depends on the device name The same with RX |
M_SSEC_CCLK_BASE_RWW_DEV1 | T_CHAR | 1st slot Remote register (RWw) refresh device name | -- | -- | RW | M,L,B,D,W,R |
M_SSEC_CCLK_BASE_RWW_NO1 | T_SHORT | 1st slot Remote register (RWw) refresh device No. | -- | -- | RW | Depends on the device name The same with RX |
M_SSEC_CCLK_BASE_SB_DEV1 | T_CHAR | 1st slot Special relay (SB) refresh device name | -- | -- | RW | M,L,B,D,W,R,SB |
M_SSEC_CCLK_BASE_SB_NO1 | T_SHORT | 1st slot Special relay (SB) refresh device No. | -- | -- | RW | Depends on the device name SB0 to SB1FF Others are the same with RX |
M_SSEC_CCLK_BASE_SW_DEV1 | T_CHAR | 1st slot Special relay (SW) refresh device name | -- | -- | RW | M,L,B,D,W,R,SW |
M_SSEC_CCLK_BASE_SW_NO1 | T_SHORT | 1st slot Special relay (SW) refresh device No. | -- | -- | RW | Depends on the device name SW0 to SW1FF Others are the same with RX |
M_SSEC_CCLK_BASE_PRTCL_VER1 | T_CHAR | 1st slot Protocol version | -- | -- | RW | 0,1 |
M_SSEC_CCLK_BASE_EXCHG_NO2 | T_CHAR | 2nd slot Station No. | -- | -- | RW | -1 to 64 |
M_SSEC_CCLK_BASE_TRANS_SP2 | T_CHAR | 2nd slot Transmission rate and mode | -- | -- | RW | 0 to 14 |
M_SSEC_CCLK_BASE_ABNML_LINK2 | T_CHAR | 2nd slot Setting of data link faulty station | -- | -- | RW | 0,1 |
M_SSEC_CCLK_BASE_PLC_STOP2 | T_CHAR | 2nd slot Setting at PLC STOP | -- | -- | RW | 0,1 |
M_SSEC_CCLK_BASE_OCCUP_BUREAUX2 | T_CHAR | 2nd slot Number of occupied stations | -- | -- | RW | 0 to 4 |
M_SSEC_CCLK_BASE_CYCLIC2 | T_CHAR | 2nd slot Extended cyclic setting | -- | -- | RW | 0,1,2,4,8 |
M_SSEC_CCLK_BASE_CONNECT_NUM2 | T_CHAR | 2nd slot Number of connected modules | -- | -- | RW | 0 to 64 |
M_SSEC_CCLK_BASE_RETRY2 | T_CHAR | 2nd slot Number of retries | -- | -- | RW | 0 to 7 |
M_SSEC_CCLK_BASE_AUTO_OPE_MATA2 | T_CHAR | 2nd slot Number of automatic return modules | -- | -- | RW | 0 to 10 |
M_SSEC_CCLK_BASE_STANDBY_MASTER2 | T_CHAR | 2nd slot Standby master station | -- | -- | RW | 0 to 64 |
M_SSEC_CCLK_BASE_NC_DOWN2 | T_CHAR | 2nd slot Operation at NC down | -- | -- | RW | 0,1 |
M_SSEC_CCLK_BASE_SCAN_MODE2 | T_CHAR | 2nd slot Scan mode | -- | -- | RW | 0,1 |
M_SSEC_CCLK_BASE_DELAY_TIME2 | T_CHAR | 2nd slot Delay time | -- | -- | RW | Fixed to 0 |
M_SSEC_CCLK_BASE_RX_DEV2 | T_CHAR | 2nd slot Remote input (RX) refresh device name | -- | -- | RW | X,M,L,B,D,W,R |
M_SSEC_CCLK_BASE_RX_NO2 | T_SHORT | 2nd slot Remote input (RX) refresh device No. | -- | -- | RW | Depends on the device name X0 to X5FF M0 to M10239 L0 to L511 B0 to B1FFF D0 to D2047 W0 to W1FFF R8300 to R9799 R9800 to R9899 |
M_SSEC_CCLK_BASE_RY_DEV2 | T_CHAR | 2nd slot Remote output (RY) refresh device name | -- | -- | RW | Y,M,L,B,D,W,R |
M_SSEC_CCLK_BASE_RY_NO2 | T_SHORT | 2nd slot Remote output (RY) refresh device No. | -- | -- | RW | Depends on the device name Y0 to Y5FF Others are the same with RX |
M_SSEC_CCLK_BASE_RWR_DEV2 | T_CHAR | 2nd slot Remote register (RWr) refresh device name | -- | -- | RW | M,L,B,D,W,R |
M_SSEC_CCLK_BASE_RWR_NO2 | T_SHORT | 2nd slot Remote register (RWr) refresh device No. | -- | -- | RW | Depends on the device name The same with RX |
M_SSEC_CCLK_BASE_RWW_DEV2 | T_CHAR | 2nd slot Remote register (RWw) refresh device name | -- | -- | RW | M,L,B,D,W,R |
M_SSEC_CCLK_BASE_RWW_NO2 | T_SHORT | 2nd slot Remote register (RWw) refresh device No. | -- | -- | RW | Depends on the device name The same with RX |
M_SSEC_CCLK_BASE_SB_DEV2 | T_CHAR | 2nd slot Special relay (SB) refresh device name | -- | -- | RW | M,L,B,D,W,R,SB |
M_SSEC_CCLK_BASE_SB_NO2 | T_SHORT | 2nd slot Special relay (SB) refresh device No. | -- | -- | RW | Depends on the device name SB0 to SB1FF Others are the same with RX |
M_SSEC_CCLK_BASE_SW_DEV2 | T_CHAR | 2nd slot Special relay (SW) refresh device name | -- | -- | RW | M,L,B,D,W,R,SW |
M_SSEC_CCLK_BASE_SW_NO2 | T_SHORT | 2nd slot Special relay (SW) refresh device No. | -- | -- | RW | Depends on the device name SW0 to SW1FF Others are the same with RX |
M_SSEC_CCLK_BASE_PRTCL_VER2 | T_CHAR | 2nd slot Protocol version | -- | -- | RW | 0,1 |
M_SSEC_CCLK_BASE_EXCHG_NO3 | T_CHAR | 3rd slot Station No. | -- | -- | RW | -1 to 64 |
M_SSEC_CCLK_BASE_TRANS_SP3 | T_CHAR | 3rd slot Transmission rate and mode | -- | -- | RW | 0 to 14 |