Spindle rotation speed (rev/min) Spindle load value Spindle No. of optical spindle Spindle No. of metal spindle The total number of optical spindles The total number of metal spindles
See: IIoT Device Driver for Mitsubishi controllers
Command Default Data Type Description Part Axis R/W Data Range M_SSEC_SPINF_REV_SPD
T_LONG Spindle rotation speed (rev/min) -- O R 0 to 999999 M_SSEC_SPINF_LOD
Spindle load value O R M_SSEC_SPINF_OPT_SP_NO
T_CHAR Spindle No. of optical spindle -- O R 1 to 4 M_SSEC_SPINF_MET_SP_NO
T_CHAR Spindle No. of metal spindle -- O R 1 to 4 M_SSEC_SPINF_OPT_SP_NUM
T_CHAR The total number of optical spindles -- -- R 0 to 4 M_SSEC_SPINF_MET_SP_NUM
T_CHAR The total number of metal spindles -- -- R 0 to 4