SPINDLE INFORMATION | MITSUBISHI M70 COMMANDS
TOP
Spindle rotation speed (rev/min) Spindle load value Spindle No. of optical spindle Spindle No. of metal spindle The total number of optical spindles The total number of metal spindles
See: IIoT Device Driver for Mitsubishi controllers
Command | Default Data Type | Description | Part | Axis | R/W | Data Range |
---|
M_SSEC_SPINF_REV_SPD
| T_LONG | Spindle rotation speed (rev/min) | -- | O | R | 0 to 999999 |
M_SSEC_SPINF_LOD
| | Spindle load value | | O | R | |
M_SSEC_SPINF_OPT_SP_NO
| T_CHAR | Spindle No. of optical spindle | -- | O | R | 1 to 4 |
M_SSEC_SPINF_MET_SP_NO
| T_CHAR | Spindle No. of metal spindle | -- | O | R | 1 to 4 |
M_SSEC_SPINF_OPT_SP_NUM
| T_CHAR | The total number of optical spindles | -- | -- | R | 0 to 4 |
M_SSEC_SPINF_MET_SP_NUM
| T_CHAR | The total number of metal spindles | -- | -- | R | 0 to 4 |