News CNCnetPDM About us Support  
       
  

CC-LINK PARAMETER STATION INFORMATION | MITSUBISHI M70 COMMANDS

TOP

Station 1 Station type Station 1 Extended cyclic setting Station 1 Number of occupied stations Station 1 Station No. Station 1 Remote station points Station 1 Reserved station Station 1 Send buffer si

See: Device Driver for Mitsubishi controllers

CommandDefault Data TypeDescriptionPartAxisR/WData Range
M_SSEC_CCLK_BRAU_CNCT_TYPE1T_CHARStation 1 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC1T_CHARStation 1 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO1T_CHARStation 1 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO1T_CHARStation 1 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM1T_CHARStation 1 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM1T_CHARStation 1 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ1T_SHORTStation 1 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ1T_SHORTStation 1 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ1T_SHORTStation 1 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE2T_CHARStation 2 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC2T_CHARStation 2 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO2T_CHARStation 2 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO2T_CHARStation 2 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM2T_CHARStation 2 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM2T_CHARStation 2 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ2T_SHORTStation 2 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ2T_SHORTStation 2 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ2T_SHORTStation 2 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE3T_CHARStation 3 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC3T_CHARStation 3 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO3T_CHARStation 3 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO3T_CHARStation 3 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM3T_CHARStation 3 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM3T_CHARStation 3 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ3T_SHORTStation 3 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ3T_SHORTStation 3 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ3T_SHORTStation 3 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE4T_CHARStation 4 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC4T_CHARStation 4 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO4T_CHARStation 4 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO4T_CHARStation 4 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM4T_CHARStation 4 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM4T_CHARStation 4 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ4T_SHORTStation 4 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ4T_SHORTStation 4 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ4T_SHORTStation 4 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE5T_CHARStation 5 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC5T_CHARStation 5 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO5T_CHARStation 5 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO5T_CHARStation 5 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM5T_CHARStation 5 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM5T_CHARStation 5 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ5T_SHORTStation 5 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ5T_SHORTStation 5 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ5T_SHORTStation 5 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE6T_CHARStation 6 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC6T_CHARStation 6 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO6T_CHARStation 6 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO6T_CHARStation 6 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM6T_CHARStation 6 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM6T_CHARStation 6 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ6T_SHORTStation 6 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ6T_SHORTStation 6 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ6T_SHORTStation 6 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE7T_CHARStation 7 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC7T_CHARStation 7 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO7T_CHARStation 7 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO7T_CHARStation 7 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM7T_CHARStation 7 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM7T_CHARStation 7 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ7T_SHORTStation 7 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ7T_SHORTStation 7 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ7T_SHORTStation 7 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE8T_CHARStation 8 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC8T_CHARStation 8 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO8T_CHARStation 8 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO8T_CHARStation 8 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM8T_CHARStation 8 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM8T_CHARStation 8 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ8T_SHORTStation 8 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ8T_SHORTStation 8 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ8T_SHORTStation 8 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE9T_CHARStation 9 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC9T_CHARStation 9 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO9T_CHARStation 9 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO9T_CHARStation 9 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM9T_CHARStation 9 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM9T_CHARStation 9 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ9T_SHORTStation 9 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ9T_SHORTStation 9 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ9T_SHORTStation 9 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE10T_CHARStation 10 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC10T_CHARStation 10 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO10T_CHARStation 10 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO10T_CHARStation 10 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM10T_CHARStation 10 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM10T_CHARStation 10 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ10T_SHORTStation 10 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ10T_SHORTStation 10 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ10T_SHORTStation 10 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE11T_CHARStation 11 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC11T_CHARStation 11 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO11T_CHARStation 11 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO11T_CHARStation 11 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM11T_CHARStation 11 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM11T_CHARStation 11 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ11T_SHORTStation 11 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ11T_SHORTStation 11 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ11T_SHORTStation 11 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE12T_CHARStation 12 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC12T_CHARStation 12 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO12T_CHARStation 12 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO12T_CHARStation 12 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM12T_CHARStation 12 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM12T_CHARStation 12 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ12T_SHORTStation 12 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ12T_SHORTStation 12 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ12T_SHORTStation 12 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE13T_CHARStation 13 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC13T_CHARStation 13 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO13T_CHARStation 13 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO13T_CHARStation 13 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM13T_CHARStation 13 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM13T_CHARStation 13 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ13T_SHORTStation 13 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ13T_SHORTStation 13 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ13T_SHORTStation 13 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE14T_CHARStation 14 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC14T_CHARStation 14 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO14T_CHARStation 14 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO14T_CHARStation 14 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM14T_CHARStation 14 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM14T_CHARStation 14 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ14T_SHORTStation 14 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ14T_SHORTStation 14 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ14T_SHORTStation 14 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE15T_CHARStation 15 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC15T_CHARStation 15 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO15T_CHARStation 15 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO15T_CHARStation 15 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM15T_CHARStation 15 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM15T_CHARStation 15 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ15T_SHORTStation 15 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ15T_SHORTStation 15 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ15T_SHORTStation 15 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE16T_CHARStation 16 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC16T_CHARStation 16 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO16T_CHARStation 16 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO16T_CHARStation 16 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM16T_CHARStation 16 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM16T_CHARStation 16 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ16T_SHORTStation 16 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ16T_SHORTStation 16 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ16T_SHORTStation 16 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE17T_CHARStation 17 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC17T_CHARStation 17 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO17T_CHARStation 17 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO17T_CHARStation 17 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM17T_CHARStation 17 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM17T_CHARStation 17 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ17T_SHORTStation 17 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ17T_SHORTStation 17 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ17T_SHORTStation 17 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE18T_CHARStation 18 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC18T_CHARStation 18 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO18T_CHARStation 18 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO18T_CHARStation 18 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM18T_CHARStation 18 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM18T_CHARStation 18 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ18T_SHORTStation 18 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ18T_SHORTStation 18 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ18T_SHORTStation 18 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE19T_CHARStation 19 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC19T_CHARStation 19 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO19T_CHARStation 19 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO19T_CHARStation 19 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM19T_CHARStation 19 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM19T_CHARStation 19 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ19T_SHORTStation 19 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ19T_SHORTStation 19 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ19T_SHORTStation 19 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE20T_CHARStation 20 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC20T_CHARStation 20 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO20T_CHARStation 20 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO20T_CHARStation 20 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM20T_CHARStation 20 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM20T_CHARStation 20 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ20T_SHORTStation 20 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ20T_SHORTStation 20 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ20T_SHORTStation 20 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE21T_CHARStation 21 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC21T_CHARStation 21 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO21T_CHARStation 21 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO21T_CHARStation 21 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM21T_CHARStation 21 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM21T_CHARStation 21 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ21T_SHORTStation 21 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ21T_SHORTStation 21 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ21T_SHORTStation 21 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE22T_CHARStation 22 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC22T_CHARStation 22 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO22T_CHARStation 22 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO22T_CHARStation 22 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM22T_CHARStation 22 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM22T_CHARStation 22 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ22T_SHORTStation 22 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ22T_SHORTStation 22 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ22T_SHORTStation 22 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE23T_CHARStation 23 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC23T_CHARStation 23 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO23T_CHARStation 23 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO23T_CHARStation 23 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM23T_CHARStation 23 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM23T_CHARStation 23 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ23T_SHORTStation 23 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ23T_SHORTStation 23 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ23T_SHORTStation 23 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE24T_CHARStation 24 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC24T_CHARStation 24 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO24T_CHARStation 24 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO24T_CHARStation 24 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM24T_CHARStation 24 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM24T_CHARStation 24 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ24T_SHORTStation 24 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ24T_SHORTStation 24 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ24T_SHORTStation 24 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE25T_CHARStation 25 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC25T_CHARStation 25 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO25T_CHARStation 25 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO25T_CHARStation 25 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM25T_CHARStation 25 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM25T_CHARStation 25 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ25T_SHORTStation 25 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ25T_SHORTStation 25 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ25T_SHORTStation 25 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE26T_CHARStation 26 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC26T_CHARStation 26 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO26T_CHARStation 26 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO26T_CHARStation 26 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM26T_CHARStation 26 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM26T_CHARStation 26 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ26T_SHORTStation 26 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ26T_SHORTStation 26 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ26T_SHORTStation 26 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE27T_CHARStation 27 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC27T_CHARStation 27 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO27T_CHARStation 27 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO27T_CHARStation 27 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM27T_CHARStation 27 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM27T_CHARStation 27 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ27T_SHORTStation 27 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ27T_SHORTStation 27 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ27T_SHORTStation 27 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE28T_CHARStation 28 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC28T_CHARStation 28 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO28T_CHARStation 28 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO28T_CHARStation 28 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM28T_CHARStation 28 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM28T_CHARStation 28 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ28T_SHORTStation 28 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ28T_SHORTStation 28 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ28T_SHORTStation 28 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE29T_CHARStation 29 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC29T_CHARStation 29 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO29T_CHARStation 29 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO29T_CHARStation 29 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM29T_CHARStation 29 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM29T_CHARStation 29 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ29T_SHORTStation 29 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ29T_SHORTStation 29 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ29T_SHORTStation 29 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE30T_CHARStation 30 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC30T_CHARStation 30 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO30T_CHARStation 30 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO30T_CHARStation 30 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM30T_CHARStation 30 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM30T_CHARStation 30 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ30T_SHORTStation 30 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ30T_SHORTStation 30 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ30T_SHORTStation 30 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE31T_CHARStation 31 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC31T_CHARStation 31 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO31T_CHARStation 31 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO31T_CHARStation 31 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM31T_CHARStation 31 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM31T_CHARStation 31 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ31T_SHORTStation 31 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ31T_SHORTStation 31 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ31T_SHORTStation 31 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE32T_CHARStation 32 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC32T_CHARStation 32 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO32T_CHARStation 32 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO32T_CHARStation 32 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM32T_CHARStation 32 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM32T_CHARStation 32 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ32T_SHORTStation 32 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ32T_SHORTStation 32 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ32T_SHORTStation 32 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE33T_CHARStation 33 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC33T_CHARStation 33 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO33T_CHARStation 33 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO33T_CHARStation 33 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM33T_CHARStation 33 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM33T_CHARStation 33 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ33T_SHORTStation 33 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ33T_SHORTStation 33 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ33T_SHORTStation 33 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE34T_CHARStation 34 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC34T_CHARStation 34 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO34T_CHARStation 34 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO34T_CHARStation 34 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM34T_CHARStation 34 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM34T_CHARStation 34 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ34T_SHORTStation 34 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ34T_SHORTStation 34 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ34T_SHORTStation 34 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE35T_CHARStation 35 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC35T_CHARStation 35 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO35T_CHARStation 35 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO35T_CHARStation 35 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM35T_CHARStation 35 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM35T_CHARStation 35 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ35T_SHORTStation 35 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ35T_SHORTStation 35 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ35T_SHORTStation 35 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE36T_CHARStation 36 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC36T_CHARStation 36 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO36T_CHARStation 36 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO36T_CHARStation 36 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM36T_CHARStation 36 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM36T_CHARStation 36 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ36T_SHORTStation 36 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ36T_SHORTStation 36 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ36T_SHORTStation 36 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE37T_CHARStation 37 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC37T_CHARStation 37 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO37T_CHARStation 37 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO37T_CHARStation 37 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM37T_CHARStation 37 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM37T_CHARStation 37 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ37T_SHORTStation 37 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ37T_SHORTStation 37 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ37T_SHORTStation 37 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE38T_CHARStation 38 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC38T_CHARStation 38 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO38T_CHARStation 38 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO38T_CHARStation 38 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM38T_CHARStation 38 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM38T_CHARStation 38 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ38T_SHORTStation 38 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ38T_SHORTStation 38 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ38T_SHORTStation 38 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE39T_CHARStation 39 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC39T_CHARStation 39 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO39T_CHARStation 39 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO39T_CHARStation 39 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM39T_CHARStation 39 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM39T_CHARStation 39 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ39T_SHORTStation 39 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ39T_SHORTStation 39 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ39T_SHORTStation 39 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE40T_CHARStation 40 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC40T_CHARStation 40 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO40T_CHARStation 40 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO40T_CHARStation 40 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM40T_CHARStation 40 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM40T_CHARStation 40 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ40T_SHORTStation 40 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ40T_SHORTStation 40 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ40T_SHORTStation 40 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE41T_CHARStation 41 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC41T_CHARStation 41 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO41T_CHARStation 41 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO41T_CHARStation 41 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM41T_CHARStation 41 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM41T_CHARStation 41 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ41T_SHORTStation 41 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ41T_SHORTStation 41 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ41T_SHORTStation 41 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE42T_CHARStation 42 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC42T_CHARStation 42 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO42T_CHARStation 42 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO42T_CHARStation 42 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM42T_CHARStation 42 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM42T_CHARStation 42 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ42T_SHORTStation 42 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ42T_SHORTStation 42 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ42T_SHORTStation 42 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE43T_CHARStation 43 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC43T_CHARStation 43 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO43T_CHARStation 43 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO43T_CHARStation 43 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM43T_CHARStation 43 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM43T_CHARStation 43 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ43T_SHORTStation 43 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ43T_SHORTStation 43 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ43T_SHORTStation 43 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE44T_CHARStation 44 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC44T_CHARStation 44 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO44T_CHARStation 44 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO44T_CHARStation 44 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM44T_CHARStation 44 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM44T_CHARStation 44 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ44T_SHORTStation 44 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ44T_SHORTStation 44 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ44T_SHORTStation 44 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE45T_CHARStation 45 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC45T_CHARStation 45 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO45T_CHARStation 45 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO45T_CHARStation 45 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM45T_CHARStation 45 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM45T_CHARStation 45 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ45T_SHORTStation 45 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ45T_SHORTStation 45 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ45T_SHORTStation 45 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE46T_CHARStation 46 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC46T_CHARStation 46 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO46T_CHARStation 46 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO46T_CHARStation 46 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM46T_CHARStation 46 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM46T_CHARStation 46 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ46T_SHORTStation 46 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ46T_SHORTStation 46 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ46T_SHORTStation 46 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE47T_CHARStation 47 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC47T_CHARStation 47 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO47T_CHARStation 47 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO47T_CHARStation 47 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM47T_CHARStation 47 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM47T_CHARStation 47 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ47T_SHORTStation 47 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ47T_SHORTStation 47 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ47T_SHORTStation 47 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE48T_CHARStation 48 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC48T_CHARStation 48 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO48T_CHARStation 48 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO48T_CHARStation 48 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM48T_CHARStation 48 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM48T_CHARStation 48 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ48T_SHORTStation 48 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ48T_SHORTStation 48 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ48T_SHORTStation 48 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE49T_CHARStation 49 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC49T_CHARStation 49 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO49T_CHARStation 49 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO49T_CHARStation 49 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM49T_CHARStation 49 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM49T_CHARStation 49 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ49T_SHORTStation 49 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ49T_SHORTStation 49 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ49T_SHORTStation 49 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE50T_CHARStation 50 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC50T_CHARStation 50 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO50T_CHARStation 50 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO50T_CHARStation 50 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM50T_CHARStation 50 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM50T_CHARStation 50 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ50T_SHORTStation 50 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ50T_SHORTStation 50 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ50T_SHORTStation 50 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE51T_CHARStation 51 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC51T_CHARStation 51 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO51T_CHARStation 51 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO51T_CHARStation 51 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM51T_CHARStation 51 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM51T_CHARStation 51 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ51T_SHORTStation 51 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ51T_SHORTStation 51 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ51T_SHORTStation 51 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE52T_CHARStation 52 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC52T_CHARStation 52 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO52T_CHARStation 52 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO52T_CHARStation 52 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM52T_CHARStation 52 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM52T_CHARStation 52 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ52T_SHORTStation 52 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ52T_SHORTStation 52 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ52T_SHORTStation 52 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE53T_CHARStation 53 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC53T_CHARStation 53 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO53T_CHARStation 53 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO53T_CHARStation 53 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM53T_CHARStation 53 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM53T_CHARStation 53 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ53T_SHORTStation 53 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ53T_SHORTStation 53 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ53T_SHORTStation 53 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE54T_CHARStation 54 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC54T_CHARStation 54 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO54T_CHARStation 54 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO54T_CHARStation 54 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM54T_CHARStation 54 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM54T_CHARStation 54 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ54T_SHORTStation 54 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ54T_SHORTStation 54 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ54T_SHORTStation 54 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE55T_CHARStation 55 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC55T_CHARStation 55 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO55T_CHARStation 55 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO55T_CHARStation 55 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM55T_CHARStation 55 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM55T_CHARStation 55 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ55T_SHORTStation 55 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ55T_SHORTStation 55 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ55T_SHORTStation 55 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE56T_CHARStation 56 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC56T_CHARStation 56 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO56T_CHARStation 56 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO56T_CHARStation 56 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM56T_CHARStation 56 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM56T_CHARStation 56 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ56T_SHORTStation 56 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ56T_SHORTStation 56 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ56T_SHORTStation 56 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE57T_CHARStation 57 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC57T_CHARStation 57 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO57T_CHARStation 57 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO57T_CHARStation 57 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM57T_CHARStation 57 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM57T_CHARStation 57 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ57T_SHORTStation 57 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ57T_SHORTStation 57 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ57T_SHORTStation 57 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE58T_CHARStation 58 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC58T_CHARStation 58 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO58T_CHARStation 58 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO58T_CHARStation 58 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM58T_CHARStation 58 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM58T_CHARStation 58 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ58T_SHORTStation 58 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ58T_SHORTStation 58 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ58T_SHORTStation 58 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE59T_CHARStation 59 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC59T_CHARStation 59 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO59T_CHARStation 59 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO59T_CHARStation 59 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM59T_CHARStation 59 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM59T_CHARStation 59 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ59T_SHORTStation 59 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ59T_SHORTStation 59 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ59T_SHORTStation 59 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE60T_CHARStation 60 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC60T_CHARStation 60 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO60T_CHARStation 60 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO60T_CHARStation 60 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM60T_CHARStation 60 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM60T_CHARStation 60 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ60T_SHORTStation 60 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ60T_SHORTStation 60 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ60T_SHORTStation 60 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE61T_CHARStation 61 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC61T_CHARStation 61 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO61T_CHARStation 61 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO61T_CHARStation 61 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM61T_CHARStation 61 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM61T_CHARStation 61 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ61T_SHORTStation 61 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ61T_SHORTStation 61 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ61T_SHORTStation 61 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE62T_CHARStation 62 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC62T_CHARStation 62 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO62T_CHARStation 62 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO62T_CHARStation 62 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM62T_CHARStation 62 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM62T_CHARStation 62 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ62T_SHORTStation 62 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ62T_SHORTStation 62 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ62T_SHORTStation 62 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE63T_CHARStation 63 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC63T_CHARStation 63 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO63T_CHARStation 63 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO63T_CHARStation 63 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM63T_CHARStation 63 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM63T_CHARStation 63 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ63T_SHORTStation 63 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ63T_SHORTStation 63 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ63T_SHORTStation 63 Automatic update buffer size----RW0, 128 to 4096
M_SSEC_CCLK_BRAU_CNCT_TYPE64T_CHARStation 64 Station type----RW0 to 5
M_SSEC_CCLK_BRAU_CNCT_CYCLIC64T_CHARStation 64 Extended cyclic setting----RW0,1,2,4,8
M_SSEC_CCLK_BRAU_CNCT_OCCUO64T_CHARStation 64 Number of occupied stations----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_EXCHG_NO64T_CHARStation 64 Station No.----RW0 to 64
M_SSEC_CCLK_BRAU_CNCT_REMOTE_NUM64T_CHARStation 64 Remote station points----RW0 to 4
M_SSEC_CCLK_BRAU_CNCT_RESERVE_NUM64T_CHARStation 64 Reserved station----RW0 to 2
M_SSEC_CCLK_BRAU_CNCT_TRANS_SZ64T_SHORTStation 64 Send buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_RECEPT_SZ64T_SHORTStation 64 Receive buffer size----RW0, 64 to 4096
M_SSEC_CCLK_BRAU_CNCT_AUTO_SZ64T_SHORTStation 64 Automatic update buffer size----RW0, 128 to 4096

 

Privacy notice

This website uses cookies. By continuing to use it you agree to our privacy policy. 

https://www.inventcom.net/support/mitsubishi-m70-commands/cc-link-parameter-station-information

Support | Mitsubishi M70 Commands | Overview

Here yo can find a list of command sections for Mitsubishi CNC Series 700/70 controllers . With our... [read more]
Support | Mitsubishi M70 Commands | Overview

Support | Mitsubishi M70 Commands | Absolute position detection data

Absolute position detection type Absolute position detection status Machine end Machine value Yet to pass (Machine value status) Automatic initial setting message Executing... [read more]
Support | Mitsubishi M70 Commands | Absolute position detection data

Support | Mitsubishi M70 Commands | Absolute position parameter

Absolute position detection method Reference Z- direction Check G28 verification width M02 verification width Current limit (%) Stopper speed Approach Near reference position +... [read more]
Support | Mitsubishi M70 Commands | Absolute position parameter

Support | Mitsubishi M70 Commands | Anshin-net 1

Telephone number to contact 1 Comment1 Telephone number to contact 2 Comment2 Telephone number to contact 3 Comment3 Anshin-net enabled MTB-net enabled Password in machining data... [read more]
Support | Mitsubishi M70 Commands | Anshin-net 1

Support | Mitsubishi M70 Commands | Anshin-net 2

Modem's telephone number Call centre’s telephone No. MTB’s telephone No. Num arrival call 1 Num arrival call 2 Num arrival call 3 Num arrival call 4 Num arrival call 5 MTB's... [read more]
Support | Mitsubishi M70 Commands | Anshin-net 2

Support | Mitsubishi M70 Commands | Anshin-net I_F

One-touch call Operator notice Arbitrary No. Notice telephone No. Anshin-net message status Message from NC service Anshin-net communication situation Anshin-net communication... [read more]
Support | Mitsubishi M70 Commands | Anshin-net I_F

Support | Mitsubishi M70 Commands | Auxiliary axis control

Operation test mode Absolute position set Position setting method Position setting status Operation mode Operation parameter group Scale Operation status Auxiliary axis reference... [read more]
Support | Mitsubishi M70 Commands | Auxiliary axis control

Support | Mitsubishi M70 Commands | Auxiliary axis drive unit monitor

Droop Rotation speed Load current MAX current 1 MAX current 2 Overload Regenerative load Current station No. Current position Target station No. Command position Auxiliary axis... [read more]
Support | Mitsubishi M70 Commands | Auxiliary axis drive unit monitor

Support | Mitsubishi M70 Commands | Axis parameter

Axis name Display axis name Increment command axis name Command unit Inch output Rotary axis Motor ccw Diameter specification axis Spindle interpolation Drive unit interface... [read more]
Support | Mitsubishi M70 Commands | Axis parameter

Support | Mitsubishi M70 Commands | Axis parameter for auxiliary axis

Motor series Regeneration option type Motor side gear ratio (machine rotation ratio) Machine side gear ratio (motor rotation ratio) Feed pitch In-position detection width... [read more]
Support | Mitsubishi M70 Commands | Axis parameter for auxiliary axis

Support | Mitsubishi M70 Commands | Axis status

Axis status (Axis removal) Axis status (Servo OFF) Axis status (1st ref) Axis status (2nd ref) Axis status (3rd ref) Axis status (4th ref) Axis status (Mirror image) Axis status... [read more]
Support | Mitsubishi M70 Commands | Axis status

Support | Mitsubishi M70 Commands | Background check

Optional block skip See: Device Driver for Mitsubishi controllers... [read more]
Support | Mitsubishi M70 Commands | Background check

Support | Mitsubishi M70 Commands | Barrier

P0 X P1 X P1 Z P2 X P2 Z P3 X See: Device Driver for Mitsubishi controllers... [read more]
Support | Mitsubishi M70 Commands | Barrier

Support | Mitsubishi M70 Commands | Base parameter

Life management count Split life management display screen Life management re-count M code Validate alternate M code M96 alternate M code M97 alternate M code Validate status... [read more]
Support | Mitsubishi M70 Commands | Base parameter

Support | Mitsubishi M70 Commands | Bit selection

Bit selection (x=0 to 195) See: Device Driver for Mitsubishi controllers... [read more]
Support | Mitsubishi M70 Commands | Bit selection

Support | Mitsubishi M70 Commands | Buffer correction

Buffer correction status Buffer correction program path See: Device Driver for Mitsubishi controllers... [read more]
Support | Mitsubishi M70 Commands | Buffer correction

Support | Mitsubishi M70 Commands | CC-Link parameter Base

1st slot Station No. 1st slot Transmission rate and mode 1st slot Setting of data link faulty station 1st slot Setting at PLC STOP 1st slot Number of occupied stations 1st slot... [read more]
Support | Mitsubishi M70 Commands | CC-Link parameter Base

Support | Mitsubishi M70 Commands | CNC information

The number of axes in a part system (Basic configuration) The number of sets of common variable (#100-) The total number of NC axes (NC) The total number of control axes... [read more]
Support | Mitsubishi M70 Commands | CNC information

Support | Mitsubishi M70 Commands | Common variable By each part system 100

100~199 (x=100~199) See: Device Driver for Mitsubishi controllers... [read more]
Support | Mitsubishi M70 Commands | Common variable By each part system 100

Support | Mitsubishi M70 Commands | Common variable Common between part systems 500

Common variable (common between part systems #400 to #999) (x=400 to 999) Common variable comment (common between part systems #500 to #519) (x=500 to 519) Common variable... [read more]
Support | Mitsubishi M70 Commands | Common variable Common between part systems 500

Support | Mitsubishi M70 Commands | Computer Link parameter

Baud rate Stop bit Parity effective Even parity Character length Hand shake Time-out set Data code Link parameter 1 Link parameter 2 Link parameter 3 Link parameter 4 Link... [read more]
Support | Mitsubishi M70 Commands | Computer Link parameter

Support | Mitsubishi M70 Commands | Coordinate system offset Extended workpiece coordinate

G54.1P1 G54.1P2 G54.1P3 G54.1P4 G54.1P5 G54.1P6 G54.1P7 G54.1P8 G54.1P9 G54.1P10 G54.1P11 G54.1P12 G54.1P13 G54.1P14 G54.1P15 G54.1P16 G54.1P17 G54.1P18 G54.1P19 G54.1P20... [read more]
Support | Mitsubishi M70 Commands | Coordinate system offset Extended workpiece coordinate

Support | Mitsubishi M70 Commands | Coordinate system offset Local coordinate

Local coordinate system offset (G54) Local coordinate system offset (G55) Local coordinate system offset (G56) Local coordinate system offset (G57) Local coordinate system offset... [read more]
Support | Mitsubishi M70 Commands | Coordinate system offset Local coordinate

Support | Mitsubishi M70 Commands | Coordinate system offset Other coordinate system

External workpiece offset (EXT) G92 coordinate system offset See: Device Driver for Mitsubishi controllers... [read more]
Support | Mitsubishi M70 Commands | Coordinate system offset Other coordinate system

Support | Mitsubishi M70 Commands | Coordinate system offset Workpiece coordinate

G54 workpiece coordinate system offset G55 workpiece coordinate system offset G56 workpiece coordinate system offset G57 workpiece coordinate system offset G58 workpiece... [read more]
Support | Mitsubishi M70 Commands | Coordinate system offset Workpiece coordinate

Support | Mitsubishi M70 Commands | Counter

Workpiece coordinate position counter Machine position counter Current position counter Relative position counter Program position counter Remaining command Skip coordinate... [read more]
Support | Mitsubishi M70 Commands | Counter

Support | Mitsubishi M70 Commands | Cumulative time

Power ON time Automatic operation time Automatic start up time External cumulative time 1 External cumulative time 2 Date Time Cycle time Machining time calculation See:... [read more]
Support | Mitsubishi M70 Commands | Cumulative time

Support | Mitsubishi M70 Commands | Ethernet parameter

Start of service IP address Subnet mask Gateway Port No. Ethernet communication parameter before conversion (Host address) Host's port No. Local IP Address Local Subnetmask IP... [read more]
Support | Mitsubishi M70 Commands | Ethernet parameter

Support | Mitsubishi M70 Commands | F modal

Program command F modal (FA) Manual feedrate (FM) Synchronous feedrate (FS) Thread cutting lead (FE) Remaining dwell time Constant surface speed control (Surface speed S) (x=1 to... [read more]
Support | Mitsubishi M70 Commands | F modal

Support | Mitsubishi M70 Commands | File information

The number of machining programs to register The number of remaining machining programs Machining program character capacity The number of remaining characters in machining... [read more]
Support | Mitsubishi M70 Commands | File information

Support | Mitsubishi M70 Commands | G modal

G code (x=Group1 to 21) Tool compensation No. of shape (diameter) compensation modal Compensation amount of shape (diameter) compensation modal Wear amount of shape (diameter)... [read more]
Support | Mitsubishi M70 Commands | G modal

Support | Mitsubishi M70 Commands | Hardware configuration

RIO unit 1 to 8 Terminal RIO unit 1 to 4 Control unit (NC card) Extension unit Terminal display (For M7) Extension bus for optional card (OPTION CARD) (For M7) External interface... [read more]
Support | Mitsubishi M70 Commands | Hardware configuration

Support | Mitsubishi M70 Commands | Input_Output parameter

Device 4 DC4/DC4 output Device 4 CR output Device 4 EIA output Device 4 Feed character Device 4 Parity V Device 4 Time-out Device 4 DR OFF Device 4 Data ASCII Device 4 Input type... [read more]
Support | Mitsubishi M70 Commands | Input_Output parameter

Support | Mitsubishi M70 Commands | Key history

Collection status of sampling Collection status of history Specification-Part system Specification-Spindle Specification-Servo Data-Hardware configuration Data-Software... [read more]
Support | Mitsubishi M70 Commands | Key history

Support | Mitsubishi M70 Commands | Ladder interface Common

Load meter name (x=1,2) Load meter graduation comment 1st line (x=1,2) Load meter unit comment (x=1,2) Load meter graduation comment 2nd line (x=1,2) Spindle standby tool comment... [read more]
Support | Mitsubishi M70 Commands | Ladder interface Common

Support | Mitsubishi M70 Commands | Life management data

Tool No. (x=1 to 1000) Status (x=1 to 1000) Method (x=1 to 1000) Length compensation (x=1 to 1000) Diameter compensation (x=1 to 1000) Used (time, the number of times, wear... [read more]
Support | Mitsubishi M70 Commands | Life management data

Support | Mitsubishi M70 Commands | Life management information

The number of tools in life management The number of registration groups in life management Data change flag in life management The maximum registration number of tools in life... [read more]
Support | Mitsubishi M70 Commands | Life management information

Support | Mitsubishi M70 Commands | Local variable

Local variable (Level0) (x=1 to 33) Local variable (Level1) (x=1 to 33) Local variable (Level2) (x=1 to 33) Local variable (Level3) (x=1 to 33) Local variable (Level4) (x=1 to... [read more]
Support | Mitsubishi M70 Commands | Local variable

Support | Mitsubishi M70 Commands | Machine error compensation parameter

Machine error compensation increment method 1st to 28th axis base axis (1 to 28) 1st to 28th axis compensation axis (1 to 28) 1st to 28th axis division point number at reference... [read more]
Support | Mitsubishi M70 Commands | Machine error compensation parameter

Support | Mitsubishi M70 Commands | Macro list

M[01] code M[01] type M[01] program No. M[02] code M[02] type M[02] program No. M[03] code M[03] type M[03] program No. M[04] code M[04] type M[04] program No. M[05] code M[05]... [read more]
Support | Mitsubishi M70 Commands | Macro list

Support | Mitsubishi M70 Commands | MSTB execution status

M command/Manual numerical command (M1) M command/Manual numerical command (M2) M command/Manual numerical command (M3) M command/Manual numerical command (M4) M command/Manual... [read more]
Support | Mitsubishi M70 Commands | MSTB execution status

Support | Mitsubishi M70 Commands | MSTB modal

S modal (S1 to S6) (x=1 to 6) T modal (T1 to T2) (x=1 to 2) M modal (M1 to M4) (x=1 to 4) B modal (B1 to B4) (x=1 to 4) See:... [read more]
Support | Mitsubishi M70 Commands | MSTB modal

Support | Mitsubishi M70 Commands | Open parameter1 long

Open parameter value 1(long) (x=1 to 896) See: Device Driver for Mitsubishi controllers... [read more]
Support | Mitsubishi M70 Commands | Open parameter1 long

Support | Mitsubishi M70 Commands | Open parameter2 double

Open parameter value 2(long) (x=1 to 896) See: Device Driver for Mitsubishi controllers... [read more]
Support | Mitsubishi M70 Commands | Open parameter2 double

Support | Mitsubishi M70 Commands | Operation parameter

Counter type 1 to 6 (x=1 to 6) Display switch between automatic/manual Edit undo enabled Auto top search Auto backup day 1 Auto backup day 2 Auto backup day 3 Auto backup day 4... [read more]
Support | Mitsubishi M70 Commands | Operation parameter

Support | Mitsubishi M70 Commands | Operation status

Macro execution level Executing verification stop Verification stop O No. Verification stop N No. Verification stop B No. Verification stop path name Operation status 1... [read more]
Support | Mitsubishi M70 Commands | Operation status

Support | Mitsubishi M70 Commands | PLC axis indexing parameter

Auxiliary axis No. The number of indexing stations Control parameter 1 Control parameter 2 Stroke length of linear axis Station offset Operation parameter group 1 Automatic... [read more]
Support | Mitsubishi M70 Commands | PLC axis indexing parameter

Support | Mitsubishi M70 Commands | PLC constant

PLC constant (x=0 to 95 / [M7] x=0 to 899) See: Device Driver for Mitsubishi controllers... [read more]
Support | Mitsubishi M70 Commands | PLC constant

Support | Mitsubishi M70 Commands | PLC counter

Counter (x=0 to 23 / [M7] x=0 to 255) Number of times of PLC counter (variable) (Only for M7) PLC counter device used status (x=0 to 256) See:... [read more]
Support | Mitsubishi M70 Commands | PLC counter

Support | Mitsubishi M70 Commands | PLC device bit

Device X (x=0 to 2815 / [M7] x=0 to 8191) Device Y (x=0 to 3583 / [M7] x=0 to 8191) Device M (x=0 to 8191 / [M7] x=0 to 10239) Device F (x=0 to 255 / [M7] x=0 to 1024) Device L... [read more]
Support | Mitsubishi M70 Commands | PLC device bit

Support | Mitsubishi M70 Commands | PLC device char

Device X (x=0 to 2815 / [M7] x=0 to 8191) Device Y (x=0 to 3583 / [M7] x=0 to 8191) Device M (x=0 to 8191 / [M7] x=0 to 10239) Device F (x=0 to 255 / [M7] x=0 to 1024) Device L... [read more]
Support | Mitsubishi M70 Commands | PLC device char

Support | Mitsubishi M70 Commands | PLC device long

Device X (x=0 to 2815 / [M7] x=0 to 8191) Device Y (x=0 to 3583 / [M7] x=0 to 8191) Device M (x=0 to 8191 / [M7] x=0 to 10239) Device F (x=0 to 255 / [M7] x=0 to 1024) Device L... [read more]
Support | Mitsubishi M70 Commands | PLC device long

Support | Mitsubishi M70 Commands | PLC device word

Device X (x=0 to 2815 / [M7] x=0 to 8191) Device Y (x=0 to 3583 / [M7] x=0 to 8191) Device M (x=0 to 8191 / [M7] x=0 to 10239) Device F (x=0 to 255 / [M7] x=0 to 1024) Device L... [read more]
Support | Mitsubishi M70 Commands | PLC device word

Support | Mitsubishi M70 Commands | PLC forced output

Device C(bit) (x=0 to 4127 / [M7] x=0 to 4255) Device E(bit) (x=0 to 127) Device F(bit) (x=0 to 255 / [M7] x=0 to 1024) Device L(bit) (x=0 to 255 / [M7] x=0 to 511) Device M(bit)... [read more]
Support | Mitsubishi M70 Commands | PLC forced output

Support | Mitsubishi M70 Commands | PLC switch

PLC switch X (IN) (x=1 to 32) PLC switch Y (OUT) (x=1 to 32) PLC switch X (IN) 1 to 16 PLC switch X (IN) 17 to 32 PLC switch Y (OUT) 1 to 16 PLC switch Y (OUT) 17 to 32 See:... [read more]
Support | Mitsubishi M70 Commands | PLC switch

Support | Mitsubishi M70 Commands | PLC timer

10ms timer (x=0 to 15 / [M7] x=0 to 703) 100ms timer (x=0 to 79 / [M7] x=0 to 703) 100ms cumulative timer (x=0 to 7 / [M7] x=0 to 63) 10ms additional extension timer... [read more]
Support | Mitsubishi M70 Commands | PLC timer

Support | Mitsubishi M70 Commands | Position switch

PSW switch 1st position switch axis name 1st position switch hypothetical dog position 1 1st position switch hypothetical dog position 2 1st position switch PSW check method... [read more]
Support | Mitsubishi M70 Commands | Position switch

Support | Mitsubishi M70 Commands | Power supply monitor

Drive unit type Drive unit serial No. Software version Operation time Alarm history 1 (Time) Alarm history 2 (Time) Alarm history 3 (Time) Alarm history 4 (Time) Alarm history 5... [read more]
Support | Mitsubishi M70 Commands | Power supply monitor

Support | Mitsubishi M70 Commands | Program execution status

Nest level of sub program in execution Disabled status: Single block/MST complete Disabled status: Feed hold/Override/Exact Path of program in execution Main O No. in execution... [read more]
Support | Mitsubishi M70 Commands | Program execution status

Support | Mitsubishi M70 Commands | Program tree

Name of main device in execution Main O No. in execution Main N No. in execution Main B No. in execution Sub 1 to 10 device name in execution (x=1 to 10) Sub 1 to 10 O number in... [read more]
Support | Mitsubishi M70 Commands | Program tree

Support | Mitsubishi M70 Commands | Program tree for graphic check

Main O number in execution for check Main N number in execution for check Main B number in execution for check See:... [read more]
Support | Mitsubishi M70 Commands | Program tree for graphic check

Support | Mitsubishi M70 Commands | Rererence position return parameter

G28 rapid traverse rate G28 approach speed Reference position shift amount Grid mask amount Grid interval Reference position direction (-) Axis with no reference position Whether... [read more]
Support | Mitsubishi M70 Commands | Rererence position return parameter

Support | Mitsubishi M70 Commands | Rotary axis configuration parameter

Orthogonal coordinate horizontal axis name Orthogonal coordinate vertical axis name Orthogonal coordinate height axis name Origin zero set coordinate selection Tool handle feed... [read more]
Support | Mitsubishi M70 Commands | Rotary axis configuration parameter

Support | Mitsubishi M70 Commands | Sampling parameter

Sampling trigger Sampling cycle The number of pieces of sampling data Sampling data buffer address Sampling data buffer size Sampling address #1 (Compatible with M625) Sampling... [read more]
Support | Mitsubishi M70 Commands | Sampling parameter

Support | Mitsubishi M70 Commands | Servo monitor

Gain Droop Rotation speed MAX current 1 MAX current 2 Overload Regenerative load Drive unit display Alarm 1 Alarm 2 Alarm 3 Alarm 4 Cycle counter Grid interval Grid amount... [read more]
Support | Mitsubishi M70 Commands | Servo monitor

Support | Mitsubishi M70 Commands | Servo parameter

SV01: Motor side gear ratio SV02: Machine side gear ratio SV03: Position loop gain 1 SV04: Position loop gain 2 SV05: Speed loop gain 1 SV06: Speed loop gain 2 SV07: Speed loop... [read more]
Support | Mitsubishi M70 Commands | Servo parameter

Support | Mitsubishi M70 Commands | Software configuration

NC system version PLC version PLCe version (Extended external alarm message) 3rd language version 4th language version Servo drive unit version Spindle drive unit version OS... [read more]
Support | Mitsubishi M70 Commands | Software configuration

Support | Mitsubishi M70 Commands | Speed information

FC (Combined speed) FA: F command feedrate FH: Head feedrate Speed display FC (Combined speed) See: Device Driver... [read more]
Support | Mitsubishi M70 Commands | Speed information

Support | Mitsubishi M70 Commands | Spindle analog adjustment

Automatic adjustment request Automatic adjustment status Manual adjustment data selection Data in manual adjustment S analog adjustment Ch0 to 3 Offset (x=0 to 3) S analog... [read more]
Support | Mitsubishi M70 Commands | Spindle analog adjustment

Support | Mitsubishi M70 Commands | Spindle information

Spindle rotation speed (rev/min) Spindle load value Spindle No. of optical spindle Spindle No. of metal spindle The total number of optical spindles The total number of metal... [read more]
Support | Mitsubishi M70 Commands | Spindle information

Support | Mitsubishi M70 Commands | Spindle monitor

Operation time Alarm history 1 (Time) Alarm history 2 (Time) Gain Droop Rotation speed Load Drive unit display Alarm 1 Alarm 2 Alarm 3 Alarm 4 Cycle counter Control input 1L... [read more]
Support | Mitsubishi M70 Commands | Spindle monitor

Support | Mitsubishi M70 Commands | Spindle parameter

SP001: Magnetic sensor and motor built-in encoder orientation-mode position loop gain SP002: Encoder orientation-mode position loop gain SP003: C-axis non-cutting position loop... [read more]
Support | Mitsubishi M70 Commands | Spindle parameter

Support | Mitsubishi M70 Commands | Spindle specification parameter

The number of limit rotation gears 00 The number of limit rotation gears 01 The number of limit rotation gears 10 The number of limit rotation gears 11 The number of maximum... [read more]
Support | Mitsubishi M70 Commands | Spindle specification parameter

Support | Mitsubishi M70 Commands | Spindle_Standby

Spindle stand by (Tool No.) (x=0 to 4) Spindle stand by (Auxiliary: D) (x=0 to 4) The number of spindles stand by to display Spindle tool's life management data Stand by tool's... [read more]
Support | Mitsubishi M70 Commands | Spindle_Standby

Support | Mitsubishi M70 Commands | Symbol Sub-section

Alarm history 3 (Time) Alarm history 4 (Time) Alarm history 5 (Time) Alarm history 6 (Time) Alarm history 7 (Time) Alarm history 8 (Time) Alarm history 1 (Alarm No.) Alarm... [read more]
Support | Mitsubishi M70 Commands | Symbol Sub-section

Support | Mitsubishi M70 Commands | Synchronization error monitor

Command error (1st set) Command error (2nd set) Command error (3rd set) FB error (1st set) FB error (2nd set) FB error (3rd set) Machine position (1st set) Machine position (2nd... [read more]
Support | Mitsubishi M70 Commands | Synchronization error monitor

Support | Mitsubishi M70 Commands | Tool compensation by each part system Type 1

Compensation data (x=1 to 999) See: Device Driver for Mitsubishi controllers... [read more]
Support | Mitsubishi M70 Commands | Tool compensation by each part system Type 1

Support | Mitsubishi M70 Commands | Tool compensation by each part system Type 2

Length (x=1 to 999) Diameter (x=1 to 999) See: Device Driver for Mitsubishi controllers... [read more]
Support | Mitsubishi M70 Commands | Tool compensation by each part system Type 2

Support | Mitsubishi M70 Commands | Tool compensation by each part system Type 3

Tool tip P (x=1 to 999) Tool length X (x=1 to 999) Tool length Y (x=1 to 999) Tool length Z (x=1 to 999) Tool tip R (x=1 to 999) Wear X (x=1 to 999) Wear Y (x=1 to 999) Wear Z... [read more]
Support | Mitsubishi M70 Commands | Tool compensation by each part system Type 3

Support | Mitsubishi M70 Commands | Tool management data

Tool No. (x=1 to 1000) Tool type (x=1 to 1000) Tool diameter (x=1 to 1000) Tool length (x=1 to 1000) Tool shape data 1 (x=1 to 1000) Tool shape data 2 (x=1 to 1000) Tool colour... [read more]
Support | Mitsubishi M70 Commands | Tool management data

Support | Mitsubishi M70 Commands | Tool measurement

TLM switch Last travel direction Last travel axis 2nd skip contact Reset input status Skip position read status TLMS status (L sys tool measure 2) Tool compensation amount... [read more]
Support | Mitsubishi M70 Commands | Tool measurement

Support | Mitsubishi M70 Commands | Tool registration

Tool registration data (Pot No.) (x=1 to 360) Tool registration data (Tool No.) (x=1 to 360) Tool registration data (Auxiliary: D) (x=1 to 360) See:... [read more]
Support | Mitsubishi M70 Commands | Tool registration
Modified: 2017-09-02