Life management count Split life management display screen Life management re-count M code Validate alternate M code M96 alternate M code M97 alternate M code Validate status trigger system Validate i
See: Device Driver for Mitsubishi controllers
Command Default Data Type Description Part Axis R/W Data Range M_SSEC_BASEPRM_TCOUNT T_LONG Life management count -- -- RW 0,1 M_SSEC_BASEPRM_TLLFSC T_CHAR Split life management display screen -- -- RW 0 to 2 M_SSEC_BASEPRM_TLRECTM T_CHAR Life management re-count M code -- -- RW 0 to 99 M_SSEC_BASEPRM_SUBM T_LONG Validate alternate M code â–³ -- RW 0,1 M_SSEC_BASEPRM_M96CODE T_CHAR M96 alternate M code â–³ -- RW 0 to 97 M_SSEC_BASEPRM_M97CODE T_CHAR M97 alternate M code â–³ -- RW 0 to 97 M_SSEC_BASEPRM_STRG T_LONG Validate status trigger system -- -- RW 0,1 M_SSEC_BASEPRM_INT2 T_LONG Validate interrupt method type 2 -- -- RW 0,1 M_SSEC_BASEPRM_MCRINT T_CHAR Macro argument initialization -- -- RW 0 to 2 M_SSEC_BASEPRM_THRWAIT T_CHAR Method for thread cutting -- -- RW 0 to 99 M_SSEC_BASEPRM_G30SLM T_LONG Invalidate soft limit (manual operation) -- -- RW 0,1 M_SSEC_BASEPRM_HSENS T_LONG Handle response switch -- -- RW 0,1 M_SSEC_BASEPRM_MIRRA T_LONG Select how to set up the length of tools on cutter tables (opposed tables) -- -- RW 0,1 M_SSEC_BASEPRM_TOMIRON T_LONG Select the mirror image of each facing turret with T command -- -- RW 0,1 M_SSEC_BASEPRM_TOFVAL T_CHAR Change macro variable -- -- RW 0,1 M_SSEC_BASEPRM_EDLKC T_LONG Edit lock C -- -- RW 0,1 M_SSEC_BASEPRM_PGLKC T_CHAR Program display lock -- -- RW 0 to 2 M_SSEC_BASEPRM_ORIGN T_LONG Origin zero inhibition -- -- RW 0,1 M_SSEC_BASEPRM_OFSFIX T_LONG Fix tool wear compensation number -- -- RW 0,1 M_SSEC_BASEPRM_REALF T_LONG Actual feedrate display -- -- RW 0,1 M_SSEC_BASEPRM_PBG90 T_LONG Playback G90 -- -- RW 0,1 M_SSEC_BASEPRM_DPRINT T_LONG DPRINT alignment -- -- RW 0,1 M_SSEC_BASEPRM_RSTVC1 T_LONG Clear variables by resetting -- -- RW 0,1 M_SSEC_BASEPRM_PWRVC1 T_LONG Clear variable by power ON -- -- RW 0,1 M_SSEC_BASEPRM_SETT T_CHAR Display selected tool number -- -- RW 0,1 M_SSEC_BASEPRM_FILDCC T_LONG Feed forward filter -- -- RW -- M_SSEC_BASEPRM_BRIGHT T_CHAR CRT brightness control -- -- RW -3 to 3 M_SSEC_BASEPRM_OFSMEM T_CHAR Select how to set up tool wear compensation screen -- -- RW 0,1 M_SSEC_BASEPRM_LCDNEG T_CHAR LCD reverse display -- -- RW 0,1 M_SSEC_BASEPRM_UNITNAME T_STR Unit name -- -- RW Alphanumeric characters M_SSEC_BASEPRM_OPTYPE T_CHAR Operation menu display valid (optype) -- -- RW 0,1 M_SSEC_BASEPRM_CNTSEL T_CHAR Coordinate value screen display counter select (Cntsel) -- -- RW 00 to 03, 10 to 13, 20 to 23, 30 to 33 M_SSEC_BASEPRM_PNOSEL T_CHAR Select screen by parameter number -- -- RW 0,1 M_SSEC_BASEPRM_EDTYPE T_CHAR Edit type selection -- -- RW 0 to 4 M_SSEC_BASEPRM_M100 T_LONG M code number 100 -- -- RW 0 to 99999999 M_SSEC_BASEPRM_M200 T_LONG M code number 200 -- -- RW 0 to 99999999 M_SSEC_BASEPRM_M300 T_LONG M code number 300 -- -- RW 0 to 99999999 M_SSEC_BASEPRM_M400 T_LONG M code number 400 -- -- RW 0 to 99999999 M_SSEC_BASEPRM_MDLKOF T_CHAR MDI setup lock -- -- RW 0,1 M_SSEC_BASEPRM_LABS T_LONG Manual ABS parameter -- -- RW 0,1 M_SSEC_BASEPRM_SCLAMP T_LONG Spindle rotation speed clamp function -- -- RW 0,1 M_SSEC_BASEPRM_SMINV T_LONG Minimum spindle rotation speed clamp type -- -- RW 0,1 M_SSEC_BASEPRM_IG611 T_CHAR Initial high accuracy -- -- RW 0,1 M_SSEC_BASEPRM_CIREFT T_LONG Arc deceleration speed change -- -- RW 0,1 M_SSEC_BASEPRM_FILDCCG0 T_LONG G00 feed forward filter -- -- RW -- M_SSEC_BASEPRM_RSTINT T_LONG Reset initial â–³ -- RW 0,1 M_SSEC_BASEPRM_INIG20 T_CHAR Initial command unit â–³ -- RW 0,1 M_SSEC_BASEPRM_FIXBDC T_CHAR Hole bottom deceleration check -- -- RW 0 to 2 M_SSEC_BASEPRM_PDOOR T_CHAR Door interlock II by each part system -- -- RW 0,1 M_SSEC_BASEPRM_DOORM T_LONG Signal input device 1 for door interlock II common between part systems -- -- RW 0x000 to 0x100 M_SSEC_BASEPRM_DOORS T_LONG Signal input device 2 for door interlock II common between part systems -- -- RW 0x000 to 0x100 M_SSEC_BASEPRM_BSCRTYP T_CHAR F0 automatic running -- -- RW Not used (0,1) M_SSEC_BASEPRM_BSCPGNO T_LONG F0 automatic running program No. -- -- RW Not used (0 to 99999999) M_SSEC_BASEPRM_FIXPRO T_LONG Fixed cycle editing -- -- RW 0,1 M_SSEC_BASEPRM_E2ROM T_LONG e2rom (Not used) -- -- RW Not used M_SSEC_BASEPRM_TEST T_LONG Simulation test -- -- RW 0,1 M_SSEC_BASEPRM_SYSNAME T_STR Part system name O -- RW Alphanumeric characters M_SSEC_BASEPRM_M2NAME T_STR Second miscellaneous code O -- RW A,B,C M_SSEC_BASEPRM_TAPROV T_SHORT Tap return override O -- RW 1 to 100 M_SSEC_BASEPRM_TAPOVR T_SHORT Tap return override O -- RW 0 to 999 M_SSEC_BASEPRM_DWLSKP T_CHAR G04 skip condition O -- RW 0 to 7 M_SSEC_BASEPRM_SKPSPD0 T_LONG G31 skip speed O -- RW 1 to 1000000 M_SSEC_BASEPRM_SKPCND1 T_CHAR G31.1 skip condition O -- RW 0 to 7 M_SSEC_BASEPRM_SKPSPD1 T_LONG G31.1 skip speed O -- RW 1 to 1000000 M_SSEC_BASEPRM_SKPCND2 T_CHAR G31.2 skip condition O -- RW 0 to 7 M_SSEC_BASEPRM_SKPSPD2 T_LONG G31.2 skip speed O -- RW 1 to 1000000 M_SSEC_BASEPRM_SKPCND3 T_CHAR G31.3 skip condition O -- RW 0 to 7 M_SSEC_BASEPRM_SKPSPD3 T_LONG G31.3 skip speed O -- RW 1 to 1000000 M_SSEC_BASEPRM_SKPCND4 T_CHAR G31.4 skip condition O -- RW 0 to 7 M_SSEC_BASEPRM_SKPSPD4 T_LONG G31.4 skip speed O -- RW 1 to 1000000 M_SSEC_BASEPRM_G96AXNO T_CHAR Constant surface speed control O -- RW 0 to 8 M_SSEC_BASEPRM_CHNCRP T_LONG Thread cutting speed O -- RW 0 to 60000 M_SSEC_BASEPRM_CLMPM T_LONG M code for clamp O -- RW 0 to 99999999 M_SSEC_BASEPRM_CLMPD T_FLOATBIN/T_LONG Dwelling time after outputting M code for unclamp O -- RW 0.000 to 99999.999 M_SSEC_BASEPRM_SPDF1 T_LONG F1 digit feedrate F1 O -- RW 1 to 1000000 M_SSEC_BASEPRM_SPDF2 T_LONG F1 digit feedrate F2 O -- RW 1 to 1000000 M_SSEC_BASEPRM_SPDF3 T_LONG F1 digit feedrate F3 O -- RW 1 to 1000000 M_SSEC_BASEPRM_SPDF4 T_LONG F1 digit feedrate F4 O -- RW 1 to 1000000 M_SSEC_BASEPRM_SPDF5 T_LONG F1 digit feedrate F5 O -- RW 1 to 1000000 M_SSEC_BASEPRM_SXCNT T_LONG Validate inclined axis control O -- RW 0,1 M_SSEC_BASEPRM_SANGL T_FLOATBIN/T_LONG Inclination angle O -- RW ±80.000 M_SSEC_BASEPRM_SZRMV T_LONG Compensation at reference position return O -- RW 0,1 M_SSEC_BASEPRM_INPOS T_CHAR Validate in-position check O -- RW 0,1 M_SSEC_BASEPRM_SYSON T_CHAR System validation setup O -- RW 0,1 M_SSEC_BASEPRM_PLCSYSON T_CHAR System validation setup (PLC) -- -- RW 0,1 M_SSEC_BASEPRM_AXISMAS T_CHAR Number of axes O -- RW 0 to SYSTEM_AXIS_NO(8) M_SSEC_BASEPRM_PLCAXISMAS T_CHAR Number of axes (PLC) -- -- RW 0 to PLCMAX(2) M_SSEC_BASEPRM_IUNIT T_STR Input setup unit O -- RW A,B,C,D,E M_SSEC_BASEPRM_PLCIUNIT T_STR Input setup unit (PLC) -- -- RW A,B,C,D,E M_SSEC_BASEPRM_CTRLUNIT T_STR Control unit O -- RW A,B,C,D,E M_SSEC_BASEPRM_PLCCTRLUNIT T_STR Control unit (PLC) -- -- RW A,B,C,D,E M_SSEC_BASEPRM_INIPLAN T_CHAR Initial plane selection O -- RW 1 to 3 M_SSEC_BASEPRM_BASE_AXIS_I T_STR Width/surface measure axis name (Base axis I) O -- RW Axis address M_SSEC_BASEPRM_BASE_AXIS_J T_STR Width/surface measure axis name (Base axis J) O -- RW Axis address M_SSEC_BASEPRM_BASE_AXIS_K T_STR Width/surface measure axis name (Base axis K) O -- RW Axis address M_SSEC_BASEPRM_HYOKOH1 T_STR Parallel axis I O -- RW Axis address M_SSEC_BASEPRM_HTATEH1 T_STR Parallel axis J O -- RW Axis address M_SSEC_BASEPRM_HTAKAH1 T_STR Parallel axis K O -- RW Axis address M_SSEC_BASEPRM_CMDTYP T_CHAR Command type â–³ -- RW 1 to 8 M_SSEC_BASEPRM_PLCSEL T_CHAR Ladder selection -- -- RW 0 to 2 M_SSEC_BASEPRM_SP_NUM T_CHAR Number of spindles -- -- RW 0 to 4 M_SSEC_BASEPRM_MINCH T_LONG M_INCH -- -- RW 0,1 M_SSEC_BASEPRM_IINCH T_LONG Initial inch -- -- RW 0,1 M_SSEC_BASEPRM_PCINCH T_CHAR PLC axis inch command -- -- RW 0,1 M_SSEC_BASEPRM_LANG T_CHAR Select language displayed -- -- RW 0 to 3,11 to 20,22 M_SSEC_BASEPRM_AUXNO T_CHAR MR-J2-CT connections -- -- RW 0 to 4 M_SSEC_BASEPRM_NSKNO T_CHAR Mega torque motor connections -- -- RW 0 to 1666 M_SSEC_BASEPRM_MEMPRG T_CHAR Definition of program save area -- -- RW 0 to 7 M_SSEC_BASEPRM_MEMTOL T_LONG Tool compensation memory common between part systems -- -- RW 0,1 M_SSEC_BASEPRM_MEMVAL T_LONG No. of common variables shared in system designation -- -- RW 0,1 M_SSEC_BASEPRM_SETUP T_SHORT Activate setup processing -- -- RW 0,1,64 M_SSEC_BASEPRM_IABSM T_LONG Initial absolute value â–³ -- RW 0,1 M_SSEC_BASEPRM_ISYNC T_LONG Initial synchronization â–³ -- RW 0,1 M_SSEC_BASEPRM_IG00 T_LONG Initial G00 â–³ -- RW 0,1 M_SSEC_BASEPRM_ABSINC T_LONG ABS/INC address â–³ -- RW 0,1 M_SSEC_BASEPRM_RADIUS T_LONG Incremental command of decimeter specification axis -- -- RW 0,1 M_SSEC_BASEPRM_DECPT2 T_LONG Decimal point type 2 -- -- RW 0,1 M_SSEC_BASEPRM_FLDIGT T_LONG Validate F1 digit -- -- RW 0,1 M_SSEC_BASEPRM_DRILZ T_LONG Specify boring axis -- -- RW 0,1 M_SSEC_BASEPRM_GMACP T_LONG Give priority to G code parameter -- -- RW 0,1 M_SSEC_BASEPRM_GEOMET T_LONG Geometric -- -- RW 0,1 M_SSEC_BASEPRM_RADERMA T_FLOATBIN/T_LONG Arc error -- -- RW 0 to 1.000 M_SSEC_BASEPRM_G00DRN T_LONG G00 dry run â–³ -- RW 0,1 M_SSEC_BASEPRM_G01INTP T_LONG G00 non-interpolation â–³ -- RW 0,1 M_SSEC_BASEPRM_G96G0 T_LONG Constant surface speed control by rapid traverse feed command -- -- RW 0,1 M_SSEC_BASEPRM_G30SL T_LONG Disable G30 soft limit -- -- RW 0,1 M_SSEC_BASEPRM_CUTRT T_LONG Short cut for rotary axis -- -- RW 0,1 M_SSEC_BASEPRM_LINRT T_LONG Linear rotary axis -- -- RW 0,1 M_SSEC_BASEPRM_MPOINT T_LONG Ignore middle point -- -- RW 0,1 M_SSEC_BASEPRM_TCHGA T_LONG Replace tools for additional axis -- -- RW 0,1 M_SSEC_BASEPRM_WMVFIN T_LONG Type of timing synchronization between part systems -- -- RW 0,1 M_SSEC_BASEPRM_TLSBK T_CHAR Select life count for single block -- -- RW 0,1 M_SSEC_BASEPRM_T0TFOF T_CHAR TF output -- -- RW 0,1 M_SSEC_BASEPRM_TLTYPE T_CHAR Tool life management type -- -- RW 1,2 M_SSEC_BASEPRM_TLDIGT T_LONG Tool wear compensation number 1-digit command -- -- RW 0,1 M_SSEC_BASEPRM_TLNO T_LONG Tool length compensation number -- -- RW 0,1 M_SSEC_BASEPRM_TRESET T_LONG Cancel tool compensation amount -- -- RW 0,1 M_SSEC_BASEPRM_TMOVE T_CHAR Tool compensation performance -- -- RW 0 to 2 M_SSEC_BASEPRM_TABSMV T_LONG Tool compensation method -- -- RW 0,1 M_SSEC_BASEPRM_TLM T_LONG Manual tool length measuring system -- -- RW 0,1 M_SSEC_BASEPRM_TLIFE T_LONG Validate life management -- -- RW 0,1 M_SSEC_BASEPRM_TCOM2 T_LONG Tool command method 2 -- -- RW 0,1 M_SSEC_BASEPRM_TSEL2 T_LONG Tool selection method 2 -- -- RW 0,1
Privacy notice This website uses cookies. By continuing to use it you agree to our privacy policy.