News CNCnetPDM About us Support  
         
  

CNC_WRHISSGNL3 | HISTORY

Description

Writes the target signal for the operation history.
Please use this function instead of cnc_wrhissgnl for Series 30i, 0i-D/F and PMi-A.

MTConnect Fanuc Adapter

Universal Fanuc Driver

Fanuc Focas Library CD

Declaration

#include "fwlib32.h" or "fwlib64.h"

FWLIBAPI short WINAPI cnc_wrhissgnl3(unsigned short FlibHndl, IODBSIG3 *sig);

Arguments

FlibHndl   [ in ]

Specify the library handle. See "Library handle" for details.

sig   [ in ]

Pointer to the IODBSIG3 structure to set the various target signal information for the operation history. The IODBSIG3 structure is as follows.

typedef struct iodbsig3 {
    short      datano;   /* Not used          */
    short      type;     /* Number of signals */
    struct {
        short   ent_no;   /* Registration sequence number */
        short   pmc_no;   /* PMC number                   */
        short   sig_no;   /* Registered signal number     */
        char    sig_name; /* Registered signal name       */
        char    mask_pat; /* Signal mask pattern          */
    } data[60];
} IODBSIG3 ;
type
Number of signals (from 1 to 60)
pmc_no
PMC number (1,2,3)
ent_no
Registration sequence number (from 1 to 60)
sig_no
Signal number to register
X:0~127
G:0~767
Y:0~127
F:0~767
sig_name
Signal address to register
0:No registration
1:X
2:G
3:Y
4:F
mask_pat
Signal mask pattern

Return

EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.

The major error codes are as follows.

Return code Meaning/Error handling
EW_ATTRIB
(4)
Data attribute error
The specification of "Number of signals"(type) is wrong.
EW_DATA
(5)
Data error
In order to get more information for this err_no return value, execute cnc_getdtailerr function. The following detail status will be set onto the member, err_no of ODBERR structure.
0:Completion status other than EW_DATA
1:"Registration sequence number"(ent_no) error
2:"Signal number"(sig_no) error
3:"Signal address"(sig_name) error
4:"PMC number"(pmc_no) error
And the wrong array number will be set onto the member, err_dtno of ODBERR.
EW_NOOPT
(6)
No option
The extended driver/library function is necessary.
EW_PARAM
(9)
CNC parameter error
  • 3195#6=0
  • As for the other return codes or the details, see "Return status of Data window function"

    CNC option

    For HSSB connection,

      This function needs the extended driver/library function.

    For Ethernet connection,

      The Ethernet function and the extended driver/library function are necessary.

      However, in case of Series 0i-D/F, 30i and PMi-A, the required CNC option is as follows.

      When Embedded Ethernet is used,

        above two optional functions are not required.

      When Ethernet board is used,

        only Ethernet function is required.

    CNC parameter

    This function is related to the following CNC parameter.
    See the manual of CNC parameter for details.

      3106#4=1,3195#6=0 (influenced by setting)

    CNC mode

    This function can be used in any CNC mode.

    Available CNC

    0i-A 0i-B/C(Note) 0i-D 0i-F 15 15i 16 18 21 16i-A 18i-A 21i-A 16i-B 18i-B 21i-B 30i-A 30i-B
    M (Machining)X X O O X X X X X X X X X X X O O
    T (Turning) X X O O X - X X X X X X X X X O O
    LC (Loader) - - - - - - X X X X X X X X X - -

    0i-D0i-F16i18i30i-A30i-B
    P (Punch press)O O X X - O
    L (Laser) - - X - - O
    W (Wire) - - X X O O


    Power Mate i-DX
    Power Mate i-HX
    Power Motion i-AO

    "O" : Both Ethernet and HSSB
    "E" : Ethernet
    "H" : HSSB
    "X" : Cannot be used
    "-" : None

    Note) 0i-C does not support the HSSB function.

    See Also

    cnc_rdhissgnl3   cnc_wrhissgnl  

    Privacy notice

    This website uses cookies. By continuing to use it you agree to our privacy policy. 

    https://www.inventcom.net/fanuc-focas-library/history/cnc_wrhissgnl3
    Fanuc Focas Library | History | cnc_clearomhis
    Description Clears the external operator's message history data. The specification for Series 30i, 0i-D/F and... [read more]
    cnc_clearomhis
    Fanuc Focas Library | History | cnc_clearophis
    Description Clears the operation history data and the alarm history data. At Series 30i 0i-D/F and PMi-A, the external operator's message history data are also... [read more]
    cnc_clearophis
    Fanuc Focas Library | History | cnc_rdalmhisno
    Description Reads the number of alarm history data. It is necessary to stop sampling the alarm history data by using... [read more]
    cnc_rdalmhisno
    Fanuc Focas Library | History | cnc_rdalmhistry
    Description Reads the alarm history data. The unit of one alarm history data is called a record.... [read more]
    cnc_rdalmhistry
    Fanuc Focas Library | History | cnc_rdalmhistry2
    Description Reads the alarm history data. Please use this function instead of cnc_rdalmhistry for Series 15i.... [read more]
    cnc_rdalmhistry2
    Fanuc Focas Library | History | cnc_rdalmhistry3
    Description Reads the alarm history data. The unit of one alarm history data is called a record.... [read more]
    cnc_rdalmhistry3
    Fanuc Focas Library | History | cnc_rdalmhistry4
    Description Reads the alarm history data. Please use this function instead of... [read more]
    cnc_rdalmhistry4
    Fanuc Focas Library | History | cnc_rdalmhistry5
    Description Reads the alarm history data. Please use this function instead of... [read more]
    cnc_rdalmhistry5
    Fanuc Focas Library | History | cnc_rdhissgnl
    Description Reads the target signal for the operation history. Please use... [read more]
    cnc_rdhissgnl
    Fanuc Focas Library | History | cnc_rdhissgnl2
    Description Reads the target signal for the operation history. Please use this function instead of... [read more]
    cnc_rdhissgnl2
    Fanuc Focas Library | History | cnc_rdhissgnl3
    Description Reads the target signal for the operation history. Please use this function instead of... [read more]
    cnc_rdhissgnl3
    Fanuc Focas Library | History | cnc_rdomhisinfo
    Description Reads the maximum number, current number and maximum string length of external operator's message history data.... [read more]
    cnc_rdomhisinfo
    Fanuc Focas Library | History | cnc_rdomhisno
    Description Reads the number of the external operator's message history data. It is necessary to execute "Stop... [read more]
    cnc_rdomhisno
    Fanuc Focas Library | History | cnc_rdomhistry
    Description Reads the external operator's message history data. Because the external operator's message history data is recorded... [read more]
    cnc_rdomhistry
    Fanuc Focas Library | History | cnc_rdomhistry2
    Description Reads the external operator's message history data. Please use this function for Series 30i, 0i-D/F and PMi-A.... [read more]
    cnc_rdomhistry2
    Fanuc Focas Library | History | cnc_rdophisno
    Description Reads the number of operation history data. It is necessary to stop sampling the operation history data by using... [read more]
    cnc_rdophisno
    Fanuc Focas Library | History | cnc_rdophistry
    Description Reads the operation history data. Please use... [read more]
    cnc_rdophistry
    Fanuc Focas Library | History | cnc_rdophistry2
    Description Reads the operation history data. Please use this function instead of... [read more]
    cnc_rdophistry2
    Fanuc Focas Library | History | cnc_rdophistry3
    Description Reads the operation history data. Please use this function instead of... [read more]
    cnc_rdophistry3
    Fanuc Focas Library | History | cnc_rdophistry4
    Description Reads the operation history data. Please use this function instead of... [read more]
    cnc_rdophistry4
    Fanuc Focas Library | History | cnc_startomhis
    Description Restarts logging the external operator's message history data. The specification for Series 30i,... [read more]
    cnc_startomhis
    Fanuc Focas Library | History | cnc_startophis
    Description Restarts sampling the operation history data and the alarm history data of CNC. In Series 30i, 0i-D/F... [read more]
    cnc_startophis
    Fanuc Focas Library | History | cnc_stopomhis
    Description Stops logging the external operator's message history data. The specification for Series 30i,... [read more]
    cnc_stopomhis
    Fanuc Focas Library | History | cnc_stopophis
    Description Stops sampling the operation history data and the alarm history data of CNC. In Series 30i/31i/32i, 0i-D/F and PMi-A, the... [read more]
    cnc_stopophis
    Fanuc Focas Library | History | cnc_wrhissgnl
    Description Writes the target signal for the operation history. Please use... [read more]
    cnc_wrhissgnl
    Fanuc Focas Library | History | cnc_wrhissgnl2
    Description Writes the target signal for the operation history. Please use this function instead of... [read more]
    cnc_wrhissgnl2
    Fanuc Focas Library | History | cnc_wrkeyhistry
    Description The specified key code is recorded in the operation history in CNC. Even... [read more]
    cnc_wrkeyhistry
    Fanuc Focas Library | History | flist_History
    CNC: Function related to history data... [read more]
    flist_History
    Modified: 2018-06-11