News CNCnetPDM About us Support  
       
  

CNC_WRHISSGNL3 | HISTORY

TOP

Description

Writes the target signal for the operation history.
Please use this function instead of cnc_wrhissgnl for Series 30i, 0i-D/F and PMi-A.

MTConnect Fanuc Adapter

Universal Fanuc Driver

Fanuc Focas Library CD

Declaration

#include "fwlib32.h" or "fwlib64.h"

FWLIBAPI short WINAPI cnc_wrhissgnl3(unsigned short FlibHndl, IODBSIG3 *sig);

Arguments

FlibHndl   [ in ]

Specify the library handle. See "Library handle" for details.

sig   [ in ]

Pointer to the IODBSIG3 structure to set the various target signal information for the operation history. The IODBSIG3 structure is as follows.


typedef struct iodbsig3 {
    short      datano;   /* Not used          */
    short      type;     /* Number of signals */
    struct {
        short   ent_no;   /* Registration sequence number */
        short   pmc_no;   /* PMC number                   */
        short   sig_no;   /* Registered signal number     */
        char    sig_name; /* Registered signal name       */
        char    mask_pat; /* Signal mask pattern          */
    } data[60];
} IODBSIG3 ;
type
Number of signals (from 1 to 60)
pmc_no
PMC number (1,2,3)
ent_no
Registration sequence number (from 1 to 60)
sig_no
Signal number to register
X:0~127
G:0~767
Y:0~127
F:0~767
sig_name
Signal address to register
0:No registration
1:X
2:G
3:Y
4:F
mask_pat
Signal mask pattern

Return

EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.

The major error codes are as follows.

Return code Meaning/Error handling
EW_ATTRIB
(4)
Data attribute error
The specification of "Number of signals"(type) is wrong.
EW_DATA
(5)
Data error
In order to get more information for this err_no return value, execute cnc_getdtailerr function. The following detail status will be set onto the member, err_no of ODBERR structure.
0:Completion status other than EW_DATA
1:"Registration sequence number"(ent_no) error
2:"Signal number"(sig_no) error
3:"Signal address"(sig_name) error
4:"PMC number"(pmc_no) error
And the wrong array number will be set onto the member, err_dtno of ODBERR.
EW_NOOPT
(6)
No option
The extended driver/library function is necessary.
EW_PARAM
(9)
CNC parameter error
  • 3195#6=0
  • As for the other return codes or the details, see "Return status of Data window function"

    CNC option

    For HSSB connection,

      This function needs the extended driver/library function.

    For Ethernet connection,

      The Ethernet function and the extended driver/library function are necessary.

      However, in case of Series 0i-D/F, 30i and PMi-A, the required CNC option is as follows.

      When Embedded Ethernet is used,

        above two optional functions are not required.

      When Ethernet board is used,

        only Ethernet function is required.

    CNC parameter

    This function is related to the following CNC parameter.
    See the manual of CNC parameter for details.

      3106#4=1,3195#6=0 (influenced by setting)

    CNC mode

    This function can be used in any CNC mode.

    Available CNC

    0i-A 0i-B/C(Note) 0i-D 0i-F 15 15i 16 18 21 16i-A 18i-A 21i-A 16i-B 18i-B 21i-B 30i-A 30i-B
    M (Machining)X X O O X X X X X X X X X X X O O
    T (Turning) X X O O X - X X X X X X X X X O O
    LC (Loader) - - - - - - X X X X X X X X X - -

    0i-D0i-F16i18i30i-A30i-B
    P (Punch press)O O X X - O
    L (Laser) - - X - - O
    W (Wire) - - X X O O


    Power Mate i-DX
    Power Mate i-HX
    Power Motion i-AO

    "O" : Both Ethernet and HSSB
    "E" : Ethernet
    "H" : HSSB
    "X" : Cannot be used
    "-" : None

    Note) 0i-C does not support the HSSB function.

    See Also

    cnc_rdhissgnl3   cnc_wrhissgnl  

    Privacy notice

    This website uses cookies. By continuing to use it you agree to our privacy policy. 

    https://www.inventcom.net/fanuc-focas-library/history/cnc_wrhissgnl3

    Fanuc Focas Library | History | cnc_clearomhis

    Clears the external operator's message history data. The specification for Series 30i, 0i-D/F and... [read more]
    Fanuc Focas Library | History | cnc_clearomhis

    Fanuc Focas Library | History | cnc_clearophis

    Clears the operation history data and the alarm history data. At Series 30i 0i-D/F and PMi-A, the external operator's message history data are also... [read more]
    Fanuc Focas Library | History | cnc_clearophis

    Fanuc Focas Library | History | cnc_rdalmhisno

    Reads the number of alarm history data. It is necessary to stop sampling the alarm history data by using... [read more]
    Fanuc Focas Library | History | cnc_rdalmhisno

    Fanuc Focas Library | History | cnc_rdalmhistry

    Reads the alarm history data. The unit of one alarm history data is called a record.... [read more]
    Fanuc Focas Library | History | cnc_rdalmhistry

    Fanuc Focas Library | History | cnc_rdalmhistry2

    Reads the alarm history data. Please use this function instead of cnc_rdalmhistry for Series 15i.... [read more]
    Fanuc Focas Library | History | cnc_rdalmhistry2

    Fanuc Focas Library | History | cnc_rdalmhistry3

    Reads the alarm history data. The unit of one alarm history data is called a record.... [read more]
    Fanuc Focas Library | History | cnc_rdalmhistry3

    Fanuc Focas Library | History | cnc_rdalmhistry4

    Reads the alarm history data. Please use this function instead of... [read more]
    Fanuc Focas Library | History | cnc_rdalmhistry4

    Fanuc Focas Library | History | cnc_rdalmhistry5

    Reads the alarm history data. Please use this function instead of... [read more]
    Fanuc Focas Library | History | cnc_rdalmhistry5

    Fanuc Focas Library | History | cnc_rdhissgnl

    Reads the target signal for the operation history. Please use... [read more]
    Fanuc Focas Library | History | cnc_rdhissgnl

    Fanuc Focas Library | History | cnc_rdhissgnl2

    Reads the target signal for the operation history. Please use this function instead of... [read more]
    Fanuc Focas Library | History | cnc_rdhissgnl2

    Fanuc Focas Library | History | cnc_rdhissgnl3

    Reads the target signal for the operation history. Please use this function instead of... [read more]
    Fanuc Focas Library | History | cnc_rdhissgnl3

    Fanuc Focas Library | History | cnc_rdomhisinfo

    Reads the maximum number, current number and maximum string length of external operator's message history data.... [read more]
    Fanuc Focas Library | History | cnc_rdomhisinfo

    Fanuc Focas Library | History | cnc_rdomhisno

    Reads the number of the external operator's message history data. It is necessary to execute Stop... [read more]
    Fanuc Focas Library | History | cnc_rdomhisno

    Fanuc Focas Library | History | cnc_rdomhistry

    Reads the external operator's message history data. Because the external operator's message history data is recorded... [read more]
    Fanuc Focas Library | History | cnc_rdomhistry

    Fanuc Focas Library | History | cnc_rdomhistry2

    Reads the external operator's message history data. Please use this function for Series 30i, 0i-D/F and PMi-A.... [read more]
    Fanuc Focas Library | History | cnc_rdomhistry2

    Fanuc Focas Library | History | cnc_rdophisno

    Reads the number of operation history data. It is necessary to stop sampling the operation history data by using... [read more]
    Fanuc Focas Library | History | cnc_rdophisno

    Fanuc Focas Library | History | cnc_rdophistry

    Reads the operation history data. Please use... [read more]
    Fanuc Focas Library | History | cnc_rdophistry

    Fanuc Focas Library | History | cnc_rdophistry2

    Reads the operation history data. Please use this function instead of... [read more]
    Fanuc Focas Library | History | cnc_rdophistry2

    Fanuc Focas Library | History | cnc_rdophistry3

    Reads the operation history data. Please use this function instead of... [read more]
    Fanuc Focas Library | History | cnc_rdophistry3

    Fanuc Focas Library | History | cnc_rdophistry4

    Reads the operation history data. Please use this function instead of... [read more]
    Fanuc Focas Library | History | cnc_rdophistry4

    Fanuc Focas Library | History | cnc_startomhis

    Restarts logging the external operator's message history data. The specification for Series 30i,... [read more]
    Fanuc Focas Library | History | cnc_startomhis

    Fanuc Focas Library | History | cnc_startophis

    Restarts sampling the operation history data and the alarm history data of CNC. In Series 30i, 0i-D/F... [read more]
    Fanuc Focas Library | History | cnc_startophis

    Fanuc Focas Library | History | cnc_stopomhis

    Stops logging the external operator's message history data. The specification for Series 30i,... [read more]
    Fanuc Focas Library | History | cnc_stopomhis

    Fanuc Focas Library | History | cnc_stopophis

    Stops sampling the operation history data and the alarm history data of CNC. In Series 30i/31i/32i, 0i-D/F and PMi-A, the... [read more]
    Fanuc Focas Library | History | cnc_stopophis

    Fanuc Focas Library | History | cnc_wrhissgnl

    Writes the target signal for the operation history. Please use... [read more]
    Fanuc Focas Library | History | cnc_wrhissgnl

    Fanuc Focas Library | History | cnc_wrhissgnl2

    Writes the target signal for the operation history. Please use this function instead of... [read more]
    Fanuc Focas Library | History | cnc_wrhissgnl2

    Fanuc Focas Library | History | cnc_wrkeyhistry

    The specified key code is recorded in the operation history in CNC. Even... [read more]
    Fanuc Focas Library | History | cnc_wrkeyhistry

    Fanuc Focas Library | History | flist_History

    CNC: Function related to history data... [read more]
    Fanuc Focas Library | History | flist_History
    Modified: 2023-12-05