Description

Reads the alarm history data. The unit of one alarm history data is called a record.

The operation history data and the alarm history data are automatically recorded on the CNC. When these data are accessed, it is necessary to temporarily stop sampling on the CNC. Therefore, it is necessary to execute "Stop logging operation history data"(cnc_stopophis) before this function is used.

And it is necessary to execute "Restart logging operation history data" (cnc_startophis) after reading to make the sampling stop time of the history data as short as possible.

The start/end record number means the relative number uesd at reading the alarm history data. These record numbers are valid only at the period from the execution of "Stop logging operation history data" until the execution of "Restart logging operation history data".

The alarm history data is acquired in old order.

MTConnect Fanuc Adapter

Universal Fanuc Driver

Fanuc Focas Library CD

Declaration

#include "fwlib32.h"

FWLIBAPI short WINAPI cnc_rdalmhistry3(unsigned short FlibHndl, unsigned short s_no, unsigned short e_no, unsigned short length, ODBAHIS3 *his);

Arguments : HSSB

FlibHndl   [ in ]

Specify the library handle. See "Library handle" for details.

s_no   [ in ]

Specify the start record number. (specify 1 or more.)

e_no   [ in ]

Specify the end record number. (specify 1 or more.)

length   [ in ]

Specify the data block length. (size of ODBAHIS3 structure)


his   [ out ]

Pointer to the ODBAHIS3 structure in which the alarm history data is stored. The ODBAHIS3 structure is as follows.


typedef struct odbahis3 {
    unsigned short s_no;        /* Start record number      */
    short          type;        /* Not used                 */
    unsigned short e_no;        /* Most recently entered    */
                                /* record number            */
    struct {
        short      dummy;       /* Not used            */
        short      alm_grp;     /* Alarm type          */
        short      alm_no;      /* Alarm number        */
        char       axis_no;     /* Axis number         */
        char       year;        /* Year                */
        char       month;       /* Month               */
        char       day;         /* Day                 */
        char       hour;        /* Hour                */
        char       minute;      /* Minute              */
        char       second;      /* Second              */
        char       dummy2;      /* Not used            */
        short      len_msg;     /* Length of alarm     */
                                /* messafe             */
        char       alm_msg[36]; /* Alarm message       */
    } alm_his[N];   /* N : Number of record */
} ODBAHIS3 ;
alm_grp
unused
alm_no
Alarm number
axis_no
Axis number (1 - maximum axis control number) It is unused for an unrelated alarm to the axis.
year
Year (0,..,99)
month
Month (1,..,12)
day
Day (1,..,31)
hour
Hour (0,..,23)
minute
Minite (0,..,59)
second
Second (0,..,59)
len_msg
Number of characters of alarm message (0 - 33)
alm_msg
Message string

Return

EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.

The major error codes are as follows.

Return code Meaning/Error handling
EW_FUNC
(1)
Unavailable
cnc_stopophis function has not been executed.
EW_LENGTH
(2)
Data block length error
Size of ODBAHIS3 structure(length) is wrong.
(e_no-s_no+1) * sizeof(data[0]) + 6 > length
EW_NUMBER
(3)
Data number error
The specification of the record number (s_no, e_no) is wrong.
EW_NOOPT
(6)
No option

As for the other return codes or the details, see "Return status of Data window function"

CNC option

For HSSB connection,

    The extended driver/library function is necessary.

CNC parameter

This function is not related to CNC parameter.

CNC mode

This function can be used in any CNC mode.

Available CNC

0i-A 0i-B/C(Note) 0i-D 0i-F 15 15i 16 18 21 16i-A 18i-A 21i-A 16i-B 18i-B 21i-B 30i-A 30i-B
M (Machining)X X X X X X X X H H H H H H X X
T (Turning) X X X X - X X X H H H H H H X X
LC (Loader) - - - - - - X X X X X X X X X - -

0i-D0i-F16i18i30i-A30i-B
P (Punch press) H H -
L (Laser) - - H - -
W (Wire) - - X X


Power Mate i-DX
Power Mate i-HX
Power Motion i-A

"O" : Both Ethernet and HSSB
"E" : Ethernet
"H" : HSSB
"X" : Cannot be used
"-" : None

Note) 0i-C does not support the HSSB function.

Privacy notice

This website uses cookies. By continuing to use it you agree to our privacy policy. 

https://www.inventcom.net/fanuc-focas-library/history/cnc_rdalmhistry3

Fanuc Focas Library | History | cnc_clearomhis

Clears the external operator's message history data. The specification for Series 30i, 0i-D/F and... [read more]
Fanuc Focas Library | History | cnc_clearomhis

Fanuc Focas Library | History | cnc_clearophis

Clears the operation history data and the alarm history data. At Series 30i 0i-D/F and PMi-A, the external operator's message history data are also... [read more]
Fanuc Focas Library | History | cnc_clearophis

Fanuc Focas Library | History | cnc_rdalmhisno

Reads the number of alarm history data. It is necessary to stop sampling the alarm history data by using... [read more]
Fanuc Focas Library | History | cnc_rdalmhisno

Fanuc Focas Library | History | cnc_rdalmhistry

Reads the alarm history data. The unit of one alarm history data is called a record.... [read more]
Fanuc Focas Library | History | cnc_rdalmhistry

Fanuc Focas Library | History | cnc_rdalmhistry2

Reads the alarm history data. Please use this function instead of cnc_rdalmhistry for Series 15i.... [read more]
Fanuc Focas Library | History | cnc_rdalmhistry2

Fanuc Focas Library | History | cnc_rdalmhistry4

Reads the alarm history data. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_rdalmhistry4

Fanuc Focas Library | History | cnc_rdalmhistry5

Reads the alarm history data. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_rdalmhistry5

Fanuc Focas Library | History | cnc_rdhissgnl

Reads the target signal for the operation history. Please use... [read more]
Fanuc Focas Library | History | cnc_rdhissgnl

Fanuc Focas Library | History | cnc_rdhissgnl2

Reads the target signal for the operation history. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_rdhissgnl2

Fanuc Focas Library | History | cnc_rdhissgnl3

Reads the target signal for the operation history. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_rdhissgnl3

Fanuc Focas Library | History | cnc_rdomhisinfo

Reads the maximum number, current number and maximum string length of external operator's message history data.... [read more]
Fanuc Focas Library | History | cnc_rdomhisinfo

Fanuc Focas Library | History | cnc_rdomhisno

Reads the number of the external operator's message history data. It is necessary to execute Stop... [read more]
Fanuc Focas Library | History | cnc_rdomhisno

Fanuc Focas Library | History | cnc_rdomhistry

Reads the external operator's message history data. Because the external operator's message history data is recorded... [read more]
Fanuc Focas Library | History | cnc_rdomhistry

Fanuc Focas Library | History | cnc_rdomhistry2

Reads the external operator's message history data. Please use this function for Series 30i, 0i-D/F and PMi-A.... [read more]
Fanuc Focas Library | History | cnc_rdomhistry2

Fanuc Focas Library | History | cnc_rdophisno

Reads the number of operation history data. It is necessary to stop sampling the operation history data by using... [read more]
Fanuc Focas Library | History | cnc_rdophisno

Fanuc Focas Library | History | cnc_rdophistry

Reads the operation history data. Please use... [read more]
Fanuc Focas Library | History | cnc_rdophistry

Fanuc Focas Library | History | cnc_rdophistry2

Reads the operation history data. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_rdophistry2

Fanuc Focas Library | History | cnc_rdophistry3

Reads the operation history data. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_rdophistry3

Fanuc Focas Library | History | cnc_rdophistry4

Reads the operation history data. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_rdophistry4

Fanuc Focas Library | History | cnc_startomhis

Restarts logging the external operator's message history data. The specification for Series 30i,... [read more]
Fanuc Focas Library | History | cnc_startomhis

Fanuc Focas Library | History | cnc_startophis

Restarts sampling the operation history data and the alarm history data of CNC. In Series 30i, 0i-D/F... [read more]
Fanuc Focas Library | History | cnc_startophis

Fanuc Focas Library | History | cnc_stopomhis

Stops logging the external operator's message history data. The specification for Series 30i,... [read more]
Fanuc Focas Library | History | cnc_stopomhis

Fanuc Focas Library | History | cnc_stopophis

Stops sampling the operation history data and the alarm history data of CNC. In Series 30i/31i/32i, 0i-D/F and PMi-A, the... [read more]
Fanuc Focas Library | History | cnc_stopophis

Fanuc Focas Library | History | cnc_wrhissgnl

Writes the target signal for the operation history. Please use... [read more]
Fanuc Focas Library | History | cnc_wrhissgnl

Fanuc Focas Library | History | cnc_wrhissgnl2

Writes the target signal for the operation history. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_wrhissgnl2

Fanuc Focas Library | History | cnc_wrhissgnl3

Writes the target signal for the operation history. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_wrhissgnl3

Fanuc Focas Library | History | cnc_wrkeyhistry

The specified key code is recorded in the operation history in CNC. Even... [read more]
Fanuc Focas Library | History | cnc_wrkeyhistry

Fanuc Focas Library | History | flist_History

CNC: Function related to history data... [read more]
Fanuc Focas Library | History | flist_History
Modified: 2023-12-05