News CNCnetPDM About us Support  
         
  

CNC_STARTOMHIS | HISTORY

Description

Restarts logging the external operator's message history data.

The specification for Series 30i, 0i-D/F and PMi-A are same as cnc_startophis.

MTConnect Fanuc Adapter

Universal Fanuc Driver

Fanuc Focas Library CD

Declaration

#include "fwlib32.h" or "fwlib64.h"

FWLIBAPI short WINAPI cnc_startomhis(unsigned short FlibHndl);

Arguments

FlibHndl   [ in ]

Specify the library handle. See "Library handle" for details.

Return

EW_OK is returned on successful completion, otherwise any value except EW_OK is returned.

The major error codes are as follows.

Return code Meaning/Error handling
EW_NOOPT
(6)
No option
The external message option or the external data input option, and the extended driver/library function are necessary.
EW_FUNC
(1)
cnc_stopomhis function has not been executed.
EW_PARAM
(9)
CNC parameter error
CNC parameter '3112#2' must be 1.

As for the other return codes or the details, see "Return status of Data window function"

CNC option

This function need the following CNC option.

    The external message option or the external data input option.

For HSSB connection,

    The extended driver/library function is necessary.

For Ethernet connection,

    The Ethernet function and the extended driver/library function are necessary.

    However, in case of Series 16i/18i/21i-B, 0i-B/C/D/F, Series 30i and PMi-A, the required CNC option is as follows.

    When Embedded Ethernet is used,

      above two optional functions are not required.

    When Ethernet board is used,

      only Ethernet function is required.

    The external message or the external data input function is necessary.

CNC parameter

This function is related to the following CNC parameter.
See the manual of CNC parameter for details.

  • Series 16/18/21, 16i/18i/21i, 0i-A/B/C
    3112#2=1 (must be set)

CNC mode

This function can be used in any CNC mode.

Available CNC

0i-A 0i-B/C(Note) 0i-D 0i-F 15 15i 16 18 21 16i-A 18i-A 21i-A 16i-B 18i-B 21i-B 30i-A 30i-B
M (Machining)H O O O X X H H H O O O O O O O O
T (Turning) H O O O X - H H H O O O O O O O O
LC (Loader) - - - - - - X X X X X X X X X - -

0i-D0i-F16i18i30i-A30i-B
P (Punch press)O O O O - O
L (Laser) - - O - - O
W (Wire) - - X X O O


Power Mate i-DX
Power Mate i-HX
Power Motion i-AO

"O" : Both Ethernet and HSSB
"E" : Ethernet
"H" : HSSB
"X" : Cannot be used
"-" : None

Note) 0i-C does not support the HSSB function.

See Also

cnc_stopomhis   cnc_rdomhisinfo   cnc_rdomhistry   cnc_clearomhis  

Privacy notice

This website uses cookies. By continuing to use it you agree to our privacy policy. 

https://www.inventcom.net/fanuc-focas-library/history/cnc_startomhis
Fanuc Focas Library | History | cnc_clearomhis
Description Clears the external operator's message history data. The specification for Series 30i, 0i-D/F and... [read more]
cnc_clearomhis
Fanuc Focas Library | History | cnc_clearophis
Description Clears the operation history data and the alarm history data. At Series 30i 0i-D/F and PMi-A, the external operator's message history data are also... [read more]
cnc_clearophis
Fanuc Focas Library | History | cnc_rdalmhisno
Description Reads the number of alarm history data. It is necessary to stop sampling the alarm history data by using... [read more]
cnc_rdalmhisno
Fanuc Focas Library | History | cnc_rdalmhistry
Description Reads the alarm history data. The unit of one alarm history data is called a record.... [read more]
cnc_rdalmhistry
Fanuc Focas Library | History | cnc_rdalmhistry2
Description Reads the alarm history data. Please use this function instead of cnc_rdalmhistry for Series 15i.... [read more]
cnc_rdalmhistry2
Fanuc Focas Library | History | cnc_rdalmhistry3
Description Reads the alarm history data. The unit of one alarm history data is called a record.... [read more]
cnc_rdalmhistry3
Fanuc Focas Library | History | cnc_rdalmhistry4
Description Reads the alarm history data. Please use this function instead of... [read more]
cnc_rdalmhistry4
Fanuc Focas Library | History | cnc_rdalmhistry5
Description Reads the alarm history data. Please use this function instead of... [read more]
cnc_rdalmhistry5
Fanuc Focas Library | History | cnc_rdhissgnl
Description Reads the target signal for the operation history. Please use... [read more]
cnc_rdhissgnl
Fanuc Focas Library | History | cnc_rdhissgnl2
Description Reads the target signal for the operation history. Please use this function instead of... [read more]
cnc_rdhissgnl2
Fanuc Focas Library | History | cnc_rdhissgnl3
Description Reads the target signal for the operation history. Please use this function instead of... [read more]
cnc_rdhissgnl3
Fanuc Focas Library | History | cnc_rdomhisinfo
Description Reads the maximum number, current number and maximum string length of external operator's message history data.... [read more]
cnc_rdomhisinfo
Fanuc Focas Library | History | cnc_rdomhisno
Description Reads the number of the external operator's message history data. It is necessary to execute "Stop... [read more]
cnc_rdomhisno
Fanuc Focas Library | History | cnc_rdomhistry
Description Reads the external operator's message history data. Because the external operator's message history data is recorded... [read more]
cnc_rdomhistry
Fanuc Focas Library | History | cnc_rdomhistry2
Description Reads the external operator's message history data. Please use this function for Series 30i, 0i-D/F and PMi-A.... [read more]
cnc_rdomhistry2
Fanuc Focas Library | History | cnc_rdophisno
Description Reads the number of operation history data. It is necessary to stop sampling the operation history data by using... [read more]
cnc_rdophisno
Fanuc Focas Library | History | cnc_rdophistry
Description Reads the operation history data. Please use... [read more]
cnc_rdophistry
Fanuc Focas Library | History | cnc_rdophistry2
Description Reads the operation history data. Please use this function instead of... [read more]
cnc_rdophistry2
Fanuc Focas Library | History | cnc_rdophistry3
Description Reads the operation history data. Please use this function instead of... [read more]
cnc_rdophistry3
Fanuc Focas Library | History | cnc_rdophistry4
Description Reads the operation history data. Please use this function instead of... [read more]
cnc_rdophistry4
Fanuc Focas Library | History | cnc_startophis
Description Restarts sampling the operation history data and the alarm history data of CNC. In Series 30i, 0i-D/F... [read more]
cnc_startophis
Fanuc Focas Library | History | cnc_stopomhis
Description Stops logging the external operator's message history data. The specification for Series 30i,... [read more]
cnc_stopomhis
Fanuc Focas Library | History | cnc_stopophis
Description Stops sampling the operation history data and the alarm history data of CNC. In Series 30i/31i/32i, 0i-D/F and PMi-A, the... [read more]
cnc_stopophis
Fanuc Focas Library | History | cnc_wrhissgnl
Description Writes the target signal for the operation history. Please use... [read more]
cnc_wrhissgnl
Fanuc Focas Library | History | cnc_wrhissgnl2
Description Writes the target signal for the operation history. Please use this function instead of... [read more]
cnc_wrhissgnl2
Fanuc Focas Library | History | cnc_wrhissgnl3
Description Writes the target signal for the operation history. Please use this function instead of... [read more]
cnc_wrhissgnl3
Fanuc Focas Library | History | cnc_wrkeyhistry
Description The specified key code is recorded in the operation history in CNC. Even... [read more]
cnc_wrkeyhistry
Fanuc Focas Library | History | flist_History
CNC: Function related to history data... [read more]
flist_History
Modified: 2018-06-11