CNC: Function related to history data

Function Name Brief description
cnc_stopophis Stop logging operation history data
cnc_startophis Restart logging operation history data
cnc_rdophisno Read number of operation history data
cnc_rdophistry Read operation history data
cnc_rdophistry2 Read operation history data (2)
cnc_rdophistry4 Read operation history data (4)
cnc_clearophis Clear operation history data
cnc_rdhissgnl Read signals related operation history
cnc_wrhissgnl Write signals related operation history
cnc_rdhissgnl2 Read signals related operation history(2)
cnc_wrhissgnl2 Write signals related operation history(2)
cnc_rdhissgnl3 Read signals related operation history(3)
cnc_wrhissgnl3 Write signals related operation history(3)
cnc_wrkeyhistry Record of key stroke
cnc_rdalmhisno Read number of alarm history data
cnc_rdalmhistry Read alarm history data
cnc_rdalmhistry2 Read alarm history data (2)
cnc_rdalmhistry5 Read alarm history data (5)
cnc_stopomhis Stop logging external operator's message history data
cnc_startomhis Restart logging external operator's message history data
cnc_rdomhisinfo Read external operator's message history data information
cnc_rdomhisno Read number of external operator's message history data
cnc_rdomhistry Read external operator's message history data
cnc_rdomhistry2 Read external operator's message history data (2)
cnc_clearomhis Clear external operator's message history data

Privacy notice

This website uses cookies. By continuing to use it you agree to our privacy policy. 

https://www.inventcom.net/fanuc-focas-library/history/flist_history

Fanuc Focas Library | History | cnc_clearomhis

Clears the external operator's message history data. The specification for Series 30i, 0i-D/F and... [read more]
Fanuc Focas Library | History | cnc_clearomhis

Fanuc Focas Library | History | cnc_clearophis

Clears the operation history data and the alarm history data. At Series 30i 0i-D/F and PMi-A, the external operator's message history data are also... [read more]
Fanuc Focas Library | History | cnc_clearophis

Fanuc Focas Library | History | cnc_rdalmhisno

Reads the number of alarm history data. It is necessary to stop sampling the alarm history data by using... [read more]
Fanuc Focas Library | History | cnc_rdalmhisno

Fanuc Focas Library | History | cnc_rdalmhistry

Reads the alarm history data. The unit of one alarm history data is called a record.... [read more]
Fanuc Focas Library | History | cnc_rdalmhistry

Fanuc Focas Library | History | cnc_rdalmhistry2

Reads the alarm history data. Please use this function instead of cnc_rdalmhistry for Series 15i.... [read more]
Fanuc Focas Library | History | cnc_rdalmhistry2

Fanuc Focas Library | History | cnc_rdalmhistry3

Reads the alarm history data. The unit of one alarm history data is called a record.... [read more]
Fanuc Focas Library | History | cnc_rdalmhistry3

Fanuc Focas Library | History | cnc_rdalmhistry4

Reads the alarm history data. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_rdalmhistry4

Fanuc Focas Library | History | cnc_rdalmhistry5

Reads the alarm history data. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_rdalmhistry5

Fanuc Focas Library | History | cnc_rdhissgnl

Reads the target signal for the operation history. Please use... [read more]
Fanuc Focas Library | History | cnc_rdhissgnl

Fanuc Focas Library | History | cnc_rdhissgnl2

Reads the target signal for the operation history. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_rdhissgnl2

Fanuc Focas Library | History | cnc_rdhissgnl3

Reads the target signal for the operation history. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_rdhissgnl3

Fanuc Focas Library | History | cnc_rdomhisinfo

Reads the maximum number, current number and maximum string length of external operator's message history data.... [read more]
Fanuc Focas Library | History | cnc_rdomhisinfo

Fanuc Focas Library | History | cnc_rdomhisno

Reads the number of the external operator's message history data. It is necessary to execute Stop... [read more]
Fanuc Focas Library | History | cnc_rdomhisno

Fanuc Focas Library | History | cnc_rdomhistry

Reads the external operator's message history data. Because the external operator's message history data is recorded... [read more]
Fanuc Focas Library | History | cnc_rdomhistry

Fanuc Focas Library | History | cnc_rdomhistry2

Reads the external operator's message history data. Please use this function for Series 30i, 0i-D/F and PMi-A.... [read more]
Fanuc Focas Library | History | cnc_rdomhistry2

Fanuc Focas Library | History | cnc_rdophisno

Reads the number of operation history data. It is necessary to stop sampling the operation history data by using... [read more]
Fanuc Focas Library | History | cnc_rdophisno

Fanuc Focas Library | History | cnc_rdophistry

Reads the operation history data. Please use... [read more]
Fanuc Focas Library | History | cnc_rdophistry

Fanuc Focas Library | History | cnc_rdophistry2

Reads the operation history data. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_rdophistry2

Fanuc Focas Library | History | cnc_rdophistry3

Reads the operation history data. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_rdophistry3

Fanuc Focas Library | History | cnc_rdophistry4

Reads the operation history data. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_rdophistry4

Fanuc Focas Library | History | cnc_startomhis

Restarts logging the external operator's message history data. The specification for Series 30i,... [read more]
Fanuc Focas Library | History | cnc_startomhis

Fanuc Focas Library | History | cnc_startophis

Restarts sampling the operation history data and the alarm history data of CNC. In Series 30i, 0i-D/F... [read more]
Fanuc Focas Library | History | cnc_startophis

Fanuc Focas Library | History | cnc_stopomhis

Stops logging the external operator's message history data. The specification for Series 30i,... [read more]
Fanuc Focas Library | History | cnc_stopomhis

Fanuc Focas Library | History | cnc_stopophis

Stops sampling the operation history data and the alarm history data of CNC. In Series 30i/31i/32i, 0i-D/F and PMi-A, the... [read more]
Fanuc Focas Library | History | cnc_stopophis

Fanuc Focas Library | History | cnc_wrhissgnl

Writes the target signal for the operation history. Please use... [read more]
Fanuc Focas Library | History | cnc_wrhissgnl

Fanuc Focas Library | History | cnc_wrhissgnl2

Writes the target signal for the operation history. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_wrhissgnl2

Fanuc Focas Library | History | cnc_wrhissgnl3

Writes the target signal for the operation history. Please use this function instead of... [read more]
Fanuc Focas Library | History | cnc_wrhissgnl3

Fanuc Focas Library | History | cnc_wrkeyhistry

The specified key code is recorded in the operation history in CNC. Even... [read more]
Fanuc Focas Library | History | cnc_wrkeyhistry
Modified: 2023-12-05