|
 |
|
MACHINING CENTER TAGS | OKUMATOP CNCnetPDM Okuma MTConnect Adapter Tag description for Machining Centers:
Coolant : MCoolantSystem1
Condition
Type
|
Sub Type
|
Tag Name
|
Id
|
Unavailable
|
|
CoolantSystem1_cond
|
MCoolantSystem1_cond
|
Electric : ElectricSystem1
Condition
Type
|
Sub Type
|
Tag Name
|
Id
|
Unavailable
|
|
ElectricSystem1_cond
|
MElectricSystem1_cond
|
Hydraulic : HydraulicSystem1
Condition
Type
|
Sub Type
|
Tag Name
|
Id
|
Unavailable
|
|
HydraulicSystem1_cond
|
MHydraulicSystem1_cond
|
Lubrication : LubricationSystem1
Condition
Type
|
Sub Type
|
Tag Name
|
Id
|
Unavailable
|
|
LubricationSystem1_cond
|
MLubricationSystem_cond
|
Pneumatic : PneumaticSystem1
Condition
Type
|
Sub Type
|
Tag Name
|
Id
|
Unavailable
|
|
PneumaticSystem1_cond
|
MPneumaticSystem1_cond
|
Rotary : A
Samples
Type
|
Sub Type
|
Tag Name
|
Id
|
Angle
|
ACTUAL
|
A1actm
|
A1actm
|
Angle
|
ACTUAL
|
A1actw
|
A1actw
|
Load
|
|
A1load
|
A1load
|
Rotary : B
Samples
Type
|
Sub Type
|
Tag Name
|
Id
|
Angle
|
ACTUAL
|
B1actm
|
B1actm
|
Angle
|
ACTUAL
|
B1actw
|
B1actw
|
Load
|
|
B1load
|
B1load
|
Rotary : C
Samples
Type
|
Sub Type
|
Tag Name
|
Id
|
RotaryVelocity
|
PROGRAMMED
|
S1cmd
|
MS1cmd
|
Load
|
|
S1load
|
MS1load
|
RotaryVelocity
|
ACTUAL
|
S1speed
|
MS1speed
|
Events
Type
|
Sub Type
|
Tag Name
|
Id
|
RotaryMode
|
|
S1Mode
|
MS1Mode
|
RotaryVelocityOverride
|
PROGRAMMED
|
S1ovr
|
MS1ovr
|
Rotary : C2
Samples
Type
|
Sub Type
|
Tag Name
|
Id
|
Angle
|
ACTUAL
|
C21actm
|
C21actm
|
Angle
|
ACTUAL
|
C21actw
|
C21actw
|
Load
|
|
C21load
|
C21load
|
Controller : Controller
Events
Type
|
Sub Type
|
Tag Name
|
Id
|
EmergencyStop
|
|
estop
|
Mestop
|
Condition
Type
|
Sub Type
|
Tag Name
|
Id
|
Unavailable
|
|
system
|
Msystem
|
Path : path
Samples
Type
|
Sub Type
|
Tag Name
|
Id
|
AccumulatedTime
|
x:CUTTING_TIME
|
p1CuttingTime
|
Mp1CuttingTime
|
PathFeedrate
|
ACTUAL
|
p1Fact
|
Mp1Fact
|
PathFeedrate
|
PROGRAMMED
|
p1Fcmd
|
Mp1Fcmd
|
PathPosition
|
ACTUAL
|
p1LPathPos
|
Mp1LPathPos
|
AccumulatedTime
|
x:OPERATING_TIME
|
p1OperatingTime
|
Mp1OperatingTime
|
AccumulatedTime
|
x:RUNNING_TIME
|
p1RunningTime
|
Mp1RunningTime
|
AccumulatedTime
|
x:SPINDLE_RUN_TIME
|
p1SpindleRunTime
|
Mp1SpindleRunTime
|
AccumulatedTime
|
x:TOTAL_CUTTING_TIME
|
p1TotalCuttingTime
|
Mp1TotalCuttingTime
|
AccumulatedTime
|
x:TOTAL_OPERATING_TIME
|
p1TotalOperatingTime
|
Mp1TotalOperatingTime
|
AccumulatedTime
|
x:TOTAL_RUNNING_TIME
|
p1TotalRunningTime
|
Mp1TotalRunningTime
|
AccumulatedTime
|
x:TOTAL_SPINDLE_RUN_TIME
|
p1TotalSpindleRunTime
|
Mp1TotalSpindleRunTime
|
Events
Type
|
Sub Type
|
Tag Name
|
Id
|
InputOutputSignal
|
x:PLC_MONITOR_IO_1
|
PlcMonitorIO_1
|
MPlcMonitorIO_1
|
InputOutputSignal
|
x:PLC_MONITOR_IO_10
|
PlcMonitorIO_10
|
MPlcMonitorIO_10
|
InputOutputSignal
|
x:PLC_MONITOR_IO_2
|
PlcMonitorIO_2
|
MPlcMonitorIO_2
|
InputOutputSignal
|
x:PLC_MONITOR_IO_3
|
PlcMonitorIO_3
|
MPlcMonitorIO_3
|
InputOutputSignal
|
x:PLC_MONITOR_IO_4
|
PlcMonitorIO_4
|
MPlcMonitorIO_4
|
InputOutputSignal
|
x:PLC_MONITOR_IO_5
|
PlcMonitorIO_5
|
MPlcMonitorIO_5
|
InputOutputSignal
|
x:PLC_MONITOR_IO_6
|
PlcMonitorIO_6
|
MPlcMonitorIO_6
|
InputOutputSignal
|
x:PLC_MONITOR_IO_7
|
PlcMonitorIO_7
|
MPlcMonitorIO_7
|
InputOutputSignal
|
x:PLC_MONITOR_IO_8
|
PlcMonitorIO_8
|
MPlcMonitorIO_8
|
InputOutputSignal
|
x:PLC_MONITOR_IO_9
|
PlcMonitorIO_9
|
MPlcMonitorIO_9
|
BlockNumber
|
|
p1BlockNumber
|
Mp1BlockNumber
|
Variables
|
x:COMMON
|
p1CommonVariable
|
Mp1CommonVariable
|
ToolNumber
|
|
p1CurrentTool
|
Mp1CurrentTool
|
Variables
|
x:CURRENT_WORKOFFSET
|
p1CurrentWorkOffset
|
Mp1CurrentWorkOffset
|
Macman
|
x:PANEL_HISTORY
|
p1MacManPanelHistory
|
Mp1MacManPanelHistory
|
OutputSignal
|
x:DRY_RUN
|
p1MachineOperationPanelOutputDryRun
|
Mp1MachineOperationPanelOutputDryRun
|
OutputSignal
|
x:MACHINE_LOCK
|
p1MachineOperationPanelOutputMachineLock
|
Mp1MachineOperationPanelOutputMachineLock
|
PalletId
|
|
p1PalletID
|
Mp1PalletID
|
ProgramHeader
|
|
p1ProgramHeader
|
Mp1ProgramHeader
|
ToolAssetId
|
|
p1ToolAssetId
|
Mp1ToolAssetId
|
Variables
|
x:WORKOFFSET_A_AXIS
|
p1WorkOffsetAAxis
|
Mp1WorkOffsetAAxis
|
Variables
|
x:WORKOFFSET_B_AXIS
|
p1WorkOffsetBAxis
|
Mp1WorkOffsetBAxis
|
Variables
|
x:WORKOFFSET_C_AXIS
|
p1WorkOffsetCAxis
|
Mp1WorkOffsetCAxis
|
Variables
|
x:WORKOFFSET_X_AXIS
|
p1WorkOffsetXAxis
|
Mp1WorkOffsetXAxis
|
Variables
|
x:WORKOFFSET_Y_AXIS
|
p1WorkOffsetYAxis
|
Mp1WorkOffsetYAxis
|
Variables
|
x:WORKOFFSET_Z_AXIS
|
p1WorkOffsetZAxis
|
Mp1WorkOffsetZAxis
|
Block
|
|
p1block
|
Mp1block
|
Line
|
|
p1line
|
Mp1line
|
PathFeedrateOverride
|
PROGRAMMED
|
pFovr
|
MpFovr
|
PathFeedrateOverride
|
RAPID
|
pFrpovr
|
MpFrpovr
|
Execution
|
|
pexecution
|
Mpexecution
|
ControllerMode
|
|
pmode
|
Mpmode
|
PartCount
|
|
ppartcount
|
Mppartcount
|
Program
|
|
pprogram
|
Mpprogram
|
Linear : X
Samples
Type
|
Sub Type
|
Tag Name
|
Id
|
Position
|
ACTUAL
|
X1actm
|
MX1actm
|
Position
|
ACTUAL
|
X1actw
|
MX1actw
|
Load
|
|
X1load
|
MX1load
|
Linear : Y
Samples
Type
|
Sub Type
|
Tag Name
|
Id
|
Position
|
ACTUAL
|
Y1actm
|
MY1actm
|
Position
|
ACTUAL
|
Y1actw
|
MY1actw
|
Load
|
|
Y1load
|
MY1load
|
Linear : Z
Samples
Type
|
Sub Type
|
Tag Name
|
Id
|
Position
|
ACTUAL
|
Z1actm
|
MZ1actm
|
Position
|
ACTUAL
|
Z1actw
|
MZ1actw
|
Load
|
|
Z1load
|
MZ1load
|
Device : OKUMA.MachiningCenter
Events
Type
|
Sub Type
|
Tag Name
|
Id
|
Availability
|
|
avail
|
Mavail
|
FunctionalMode
|
|
fmode
|
Mfmode
|
AssetChanged
|
|
|
OKUMA.MachiningCenter.123456_asset_chg
|
AssetRemoved
|
|
|
OKUMA.MachiningCenter.123456_asset_rem
|
Privacy noticeThis website uses cookies. By continuing to use it you agree to our privacy policy.  |
Support | Okuma | Overview CNCnetPDM for Okuma machines allows you to acquire machine-, process and quality-data in near real time and output it to an OPC UA compliant server, various databases, MTConnect... [read more] |  |
Support | Okuma | Machine Data To report Okuma machine data to your applications you have to be able to acquire it from your devices. For Okuma machine tools equipped with OSP P controllers version 100 or... [read more] |  |
Support | Okuma | Device Driver The CNCnetPDM Okuma MTConnect device driver allows monitoring of machine- process- and quality-data in near real time from Okuma machines with OSP P controllers version OSP-P 100... [read more] |  |
Support | Okuma | Standard Lathe Tags CNCnetPDM Okuma MTConnect Adapter Tag for Standard Lathe machines: Coolant : LCoolantSystem1 Condition... [read more] |  |
Support | Okuma | Lathe 2 Sides Tags CNCnetPDM Okuma MTConnect Adapter Tag for 2-Sides Lathe machines: Rotary : C Samples... [read more] |  |
Support | Okuma | Grinder Tags CNCnetPDM Okuma MTConnect Adapter Tag for Grinders : Rotary : B Samples Type... [read more] |  |
Modified: 2023-07-05 |
|