News CNCnetPDM About us Support  
       
  

PLC DEVICE | CITIZEN MITSUBISHI COMMANDS

TOP

Device B (one shot) link relay Device C (one shot) counter input Device C (one shot) counter output Device E (one shot) special relay Device SM (one shot) special relay Device F (one shot) temporary s

See: IIoT Device Driver for Citizen Mitsubishi controllers

CommandDescription
SECT_DEV_B_BIT_1SHOT(x)
Device B (one shot) link relay
SECT_DEV_CI_BIT_1SHOT(x)
Device C (one shot) counter input
SECT_DEV_CO_BIT_1SHOT(x)
Device C (one shot) counter output
SECT_DEV_E_BIT_1SHOT(x)
Device E (one shot) special relay
SECT_DEV_SM_BIT_1SHOT(x)
Device SM (one shot) special relay
SECT_DEV_F_BIT_1SHOT(x)
Device F (one shot) temporary storage
SECT_DEV_L_BIT_1SHOT(x)
Device L (one shot) latch relay
SECT_DEV_M_BIT_1SHOT(x)
Device M (one shot) temporary storage
SECT_DEV_STI_BIT_1SHOT(x)
Device S (one shot)
SECT_DEV_STO_BIT_1SHOT(x)
Device S (one shot)
SECT_DEV_TI_BIT_1SHOT(x)
Device T (one shot) timer input
SECT_DEV_TO_BIT_1SHOT(x)
Device T (one shot) timer output
SECT_DEV_V_BIT_1SHOT(x)
Device V (one shot) edge relay
SECT_DEV_X_BIT_1SHOT(x)
Device X (one shot) Input signal to PLC (for one line)
SECT_DEV_Y_BIT_1SHOT(x)
Device Y (one shot) Output signal from PLC (for one line)
SECT_DEV_SB_BIT_1SHOT(x)
Special relay for device SB (one shot) link
SECT_DEV_B_BIT_MODAL(x)
Device B (modal) link relay
SECT_DEV_CI_BIT_MODAL(x)
Device C (modal) counter input
SECT_DEV_CO_BIT_MODAL(x)
Device C (modal) counter output
SECT_DEV_E_BIT_MODAL(x)
Device E (modal) special relay
SECT_DEV_SM_BIT_MODAL(x)
Device SM (modal) special relay
SECT_DEV_F_BIT_MODAL(x)
Device F (modal) temporary storage
SECT_DEV_L_BIT_MODAL(x)
Device L (modal) latch relay
SECT_DEV_M_BIT_MODAL(x)
Device M (modal) temporary storage
SECT_DEV_STI_BIT_MODAL(x)
Device S (one shot)
SECT_DEV_STO_BIT_MODAL(x)
Device S (one shot)
SECT_DEV_TI_BIT_MODAL(x)
Device T (modal) timer input
SECT_DEV_TO_BIT_MODAL(x)
Device T (modal) timer output
SECT_DEV_V_BIT_MODAL(x)
Device V (modal) edge relay
SECT_DEV_X_BIT_MODAL(x)
Device X (modal) Input signal to PLC (for one channel)
SECT_DEV_Y_BIT_MODAL(x)
Device Y (modal) Output signal from PLC (for one channel)
SECT_DEV_SB_BIT_MODAL(x)
Device SB (modal) special relay for link
SECT_DEV_B_CHAR_1SHOT(x)
Device B (one shot) link relay
SECT_DEV_CI_CHAR_1SHOT(x)
Device C (one shot) counter input
SECT_DEV_CO_CHAR_1SHOT(x)
Device C (one shot) counter output
SECT_DEV_E_CHAR_1SHOT(x)
Device E (one shot) special relay
SECT_DEV_SM_CHAR_1SHOT(x)
Device SM (one shot) special relay
SECT_DEV_F_CHAR_1SHOT(x)
Device F (one shot) temporary storage
SECT_DEV_L_CHAR_1SHOT(x)
Device L (one shot) latch relay
SECT_DEV_M_CHAR_1SHOT(x)
Device M (one shot) temporary storage
SECT_DEV_STI_CHAR_1SHOT(x)
Device S (one shot)
SECT_DEV_STO_CHAR_1SHOT(x)
Device S (one shot)
SECT_DEV_TI_CHAR_1SHOT(x)
Device T (one shot) timer input
SECT_DEV_TO_CHAR_1SHOT(x)
Device T (one shot) timer output
SECT_DEV_V_CHAR_1SHOT(x)
Device V (one shot) edge relay
SECT_DEV_X_CHAR_1SHOT(x)
Device X (one shot) Input signal to PLC (for one line)
SECT_DEV_Y_CHAR_1SHOT(x)
Device Y (one shot) Output signal from PLC (for one line)
SECT_DEV_SB_CHAR_1SHOT(x)
Special relay for device SB (one shot) link
SECT_DEV_B_CHAR_MODAL(x)
Device B (modal) link relay
SECT_DEV_CI_CHAR_MODAL(x)
Device C (modal) counter input
SECT_DEV_CO_CHAR_MODAL(x)
Device C (modal) counter output
SECT_DEV_E_CHAR_MODAL(x)
Device E (modal) special relay
SECT_DEV_SM_CHAR_MODAL(x)
Device SM (modal) special relay
SECT_DEV_F_CHAR_MODAL(x)
Device F (modal) temporary storage
SECT_DEV_STI_CHAR_MODAL(x)
Device S (one shot)
SECT_DEV_TI_CHAR_MODAL(x)
Device T (modal) timer input
SECT_DEV_TO_CHAR_MODAL(x)
Device T (modal) timer output
SECT_DEV_V_CHAR_MODAL(x)
Device V (modal) edge relay
SECT_DEV_X_CHAR_MODAL(x)
Device X (modal) Input signal to PLC (for one channel)
SECT_DEV_Y_CHAR_MODAL(x)
Device Y (modal) Output signal from PLC (for one channel)
SECT_DEV_SB_CHAR_MODAL(x)
Device SB (modal) special relay for link
SECT_DEV_B_SHORT_1SHOT(x)
Device B (one shot) link relay
SECT_DEV_CI_SHORT_1SHOT(x)
Device C (one shot) counter input
SECT_DEV_CO_SHORT_1SHOT(x)
Device C (one shot) counter output
SECT_DEV_CA_SHORT_1SHOT(x)
Device C (one-shot) counter current value
SECT_DEV_CS_SHORT_1SHOT(x)
Device C (one-shot) counter setting value
SECT_DEV_D_SHORT_1SHOT(x)
Data register (one shot)
SECT_DEV_E_SHORT_1SHOT(x)
Device E (one shot) special relay
SECT_DEV_SM_SHORT_1SHOT(x)
Device SM (one shot) special relay
SECT_DEV_F_SHORT_1SHOT(x)
Device F (one shot) temporary storage
SECT_DEV_L_SHORT_1SHOT(x)
Device L (one shot) latch relay
SECT_DEV_M_SHORT_1SHOT(x)
Device M (one shot) temporary storage
SECT_DEV_R_SHORT_1SHOT(x)
Device R (one shot) file register
SECT_DEV_STI_SHORT_1SHOT(x)
Device S (one shot)
SECT_DEV_STO_SHORT_1SHOT(x)
Device S (one shot)
SECT_DEV_STA_SHORT_1SHOT(x)
Device S (one shot)
SECT_DEV_STB_SHORT_1SHOT(x)
Device S (one shot)
SECT_DEV_STS_SHORT_1SHOT(x)
Device S (one shot)
SECT_DEV_TI_SHORT_1SHOT(x)
Device T (one shot) timer input
SECT_DEV_TO_SHORT_1SHOT(x)
Device T (one shot) timer output
SECT_DEV_TA_SHORT_1SHOT(x)
Device T (one shot) timer current value
SECT_DEV_TB_SHORT_1SHOT(x)
Device T (one shot) timer internal value
SECT_DEV_TS_SHORT_1SHOT(x)
Device T (one shot) timer setting value
SECT_DEV_V_SHORT_1SHOT(x)
Device V (one shot) link relay
SECT_DEV_W_SHORT_1SHOT(x)
Device W (one shot) link relay
SECT_DEV_X_SHORT_1SHOT(x)
Device X (one shot) Input signal to PLC (for one line)
SECT_DEV_Y_SHORT_1SHOT(x)
Device Y (one shot) Output signal from PLC (for one line)
SECT_DEV_SB_SHORT_1SHOT(x)
Device SB (one shot) link relay
SECT_DEV_SD_SHORT_1SHOT(x)
Device SD (one shot) link relay
SECT_DEV_SW_SHORT_1SHOT(x)
Device SW (one shot) link relay
SECT_DEV_B_SHORT_MODAL(x)
Device B (modal) link relay
SECT_DEV_CI_SHORT_MODAL(x)
Device C (modal) counter input
SECT_DEV_CO_SHORT_MODAL(x)
Device C (modal) counter output
SECT_DEV_CA_SHORT_MODAL(x)
Device C (modal) counter current value
SECT_DEV_CS_SHORT_MODAL(x)
Device C (modal) counter setting value
SECT_DEV_D_SHORT_MODAL(x)
Data register (modal)
SECT_DEV_E_SHORT_MODAL(x)
Device E (modal) special relay
SECT_DEV_SM_SHORT_MODAL(x)
Device SM (modal) special relay
SECT_DEV_F_SHORT_MODAL(x)
Device F (modal) temporary storage
SECT_DEV_L_SHORT_MODAL(x)
Device L (modal) latch relay
SECT_DEV_M_SHORT_MODAL(x)
Device M (modal) temporary storage
SECT_DEV_R_SHORT_MODAL(x)
Device R (modal) file register
SECT_DEV_STI_SHORT_MODAL(x)
Device S (one shot)
SECT_DEV_STO_SHORT_MODAL(x)
Device S (one shot)
SECT_DEV_STA_SHORT_MODAL(x)
Device S (one shot)
SECT_DEV_STB_SHORT_MODAL(x)
Device S (one shot)
SECT_DEV_STS_SHORT_MODAL(x)
Device S (one shot)
SECT_DEV_TI_SHORT_MODAL(x)
Device T (modal) timer input
SECT_DEV_TO_SHORT_MODAL(x)
Device T (modal) timer output
SECT_DEV_TA_SHORT_MODAL(x)
Device T (modal) timer current value
SECT_DEV_TB_SHORT_MODAL(x)
Device T (modal) Internal value of timer
SECT_DEV_TS_SHORT_MODAL(x)
Device T (modal) timer setting value
SECT_DEV_V_SHORT_MODAL(x)
Device V (modal) link relay
SECT_DEV_W_SHORT_MODAL(x)
Device W (modal) link relay
SECT_DEV_X_SHORT_MODAL(x)
Device X (modal) Input signal to PLC (for one channel)
SECT_DEV_Y_SHORT_MODAL(x)
Device Y (modal) Output signal from PLC (for one channel)
SECT_DEV_SB_SHORT_MODAL(x)
Device SB (modal) link relay
SECT_DEV_SD_SHORT_MODAL(x)
Device SD (modal) link relay
SECT_DEV_SW_SHORT_MODAL(x)
Device SW (modal) link relay
SECT_DEV_B_LONG_1SHOT(x)
Device B (one shot) link relay
SECT_DEV_CI_LONG_1SHOT(x)
Device C (one shot) counter input
SECT_DEV_CO_LONG_1SHOT(x)
Device C (one shot) counter output
SECT_DEV_CA_LONG_1SHOT(x)
Device C (one-shot) counter current value
SECT_DEV_CS_LONG_1SHOT(x)
Device C (one-shot) counter setting value
SECT_DEV_D_LONG_1SHOT(x)
Data register (one shot)
SECT_DEV_E_LONG_1SHOT(x)
Device E (one shot) special relay
SECT_DEV_SM_LONG_1SHOT(x)
Device SM (one shot) special relay
SECT_DEV_F_LONG_1SHOT(x)
Device F (one shot) temporary storage
SECT_DEV_L_LONG_1SHOT(x)
Device L (one shot) latch relay
SECT_DEV_M_LONG_1SHOT(x)
Device M (one shot) temporary storage
SECT_DEV_R_LONG_1SHOT(x)
Device R (one shot) file register
SECT_DEV_STI_LONG_1SHOT(x)
Device S (one shot)
SECT_DEV_STO_LONG_1SHOT(x)
Device S (one shot)
SECT_DEV_STA_LONG_1SHOT(x)
Device S (one shot)
SECT_DEV_STB_LONG_1SHOT(x)
Device S (one shot)
SECT_DEV_STS_LONG_1SHOT(x)
Device S (one shot)
SECT_DEV_TI_LONG_1SHOT(x)
Device T (one shot) timer input
SECT_DEV_TO_LONG_1SHOT(x)
Device T (one shot) timer output
SECT_DEV_TA_LONG_1SHOT(x)
Device T (one shot) timer current value
SECT_DEV_TB_LONG_1SHOT(x)
Device T (one shot) timer internal value
SECT_DEV_TS_LONG_1SHOT(x)
Device T (one shot) timer setting value
SECT_DEV_V_LONG_1SHOT(x)
Device V (one shot) link relay
SECT_DEV_W_LONG_1SHOT(x)
Device W (one shot) link relay
SECT_DEV_X_LONG_1SHOT(x)
Device X (one shot) Input signal to PLC (for one line)
SECT_DEV_Y_LONG_1SHOT(x)
Device Y (one shot) Output signal from PLC (for one line)
SECT_DEV_SB_LONG_1SHOT(x)
Device SB (one shot) link relay
SECT_DEV_SD_LONG_1SHOT(x)
Device SD (one shot) link relay
SECT_DEV_SW_LONG_1SHOT(x)
Device SW (one shot) link relay
SECT_DEV_B_LONG_MODAL(x)
Device B (modal) link relay
SECT_DEV_CI_LONG_MODAL(x)
Device C (modal) counter input
SECT_DEV_CO_LONG_MODAL(x)
Device C (modal) counter output
SECT_DEV_CA_LONG_MODAL(x)
Device C (modal) counter current value
SECT_DEV_CS_LONG_MODAL(x)
Device C (modal) counter setting value
SECT_DEV_D_LONG_MODAL(x)
Data register (modal)
SECT_DEV_E_LONG_MODAL(x)
Device E (modal) special relay
SECT_DEV_SM_LONG_MODAL(x)
Device SM (modal) special relay
SECT_DEV_F_LONG_MODAL(x)
Device F (modal) temporary storage
SECT_DEV_L_LONG_MODAL(x)
Device L (modal) latch relay
SECT_DEV_M_LONG_MODAL(x)
Device M (modal) temporary storage
SECT_DEV_R_LONG_MODAL(x)
Device R (modal) file register
SECT_DEV_STI_LONG_MODAL(x)
Device S (one shot)
SECT_DEV_STO_LONG_MODAL(x)
Device S (one shot)
SECT_DEV_STA_LONG_MODAL(x)
Device S (one shot)
SECT_DEV_STB_LONG_MODAL(x)
Device S (one shot)
SECT_DEV_STS_LONG_MODAL(x)
Device S (one shot)
SECT_DEV_TI_LONG_MODAL(x)
Device T (modal) timer input
SECT_DEV_TO_LONG_MODAL(x)
Device T (modal) timer output
SECT_DEV_TA_LONG_MODAL(x)
Device T (modal) timer current value
SECT_DEV_TB_LONG_MODAL(x)
Device T (modal) Internal value of timer
SECT_DEV_TS_LONG_MODAL(x)
Device T (modal) timer setting value
SECT_DEV_V_LONG_MODAL(x)
Device V (modal) link relay
SECT_DEV_W_LONG_MODAL(x)
Device W (modal) link relay
SECT_DEV_X_LONG_MODAL(x)
Device X (modal) Input signal to PLC (for one channel)
SECT_DEV_Y_LONG_MODAL(x)
Device Y (modal) Output signal from PLC (for one channel)
SECT_DEV_SB_LONG_MODAL(x)
Device SB (modal) link relay
SECT_DEV_SD_LONG_MODAL(x)
Device SD (modal) link relay
SECT_DEV_SW_LONG_MODAL(x)
Device SW (modal) link relay

 

Privacy notice

This website uses cookies. By continuing to use it you agree to our privacy policy. 

https://www.inventcom.net/support/citizen-mitsubishi-commands/plc-device

Support | Citizen Mitsubishi Commands | Overview

Here yo can find a list of command sections for Mitsubishi CNC controllers on Citizen and... [read more]
Support | Citizen Mitsubishi Commands | Overview

Support | Citizen Mitsubishi Commands | Axis independent parameter

Axis name Basic Specification Para # 11 abson Absolute position set # 1 SET Absolute position set # 2 base Absolute position set SET_FIN Machine end E - G Axis specification para... [read more]
Support | Citizen Mitsubishi Commands | Axis independent parameter

Support | Citizen Mitsubishi Commands | Buffer correction

Start buffer correction Buffer correction end Acquire buffer correction status Buffer correction point acquisition (O number) Acquire buffer correction point (block) Buffer... [read more]
Support | Citizen Mitsubishi Commands | Buffer correction

Support | Citizen Mitsubishi Commands | Data on alarm

Absolute value alarm: attribute              : Sub 1              : Sub 2              :number Servo alarm: attribute              : Sub 1              : Sub 2... [read more]
Support | Citizen Mitsubishi Commands | Data on alarm

Support | Citizen Mitsubishi Commands | Data on arbitrary axis superposition

Arbitrary superimposition control data 1 Arbitrary superimposition control data 2 Arbitrary superimposition control data 3 Arbitrary superimposition control data 4 Arbitrary... [read more]
Support | Citizen Mitsubishi Commands | Data on arbitrary axis superposition

Support | Citizen Mitsubishi Commands | Data on current NC program and running status

O: Program number (main program) N: Sequence number (main program) B: Block number (main program) O: Program number (subprogram) N: Sequence number (subprogram) B: Block number... [read more]
Support | Citizen Mitsubishi Commands | Data on current NC program and running status

Support | Citizen Mitsubishi Commands | Data on date time etc

Power on time Automatic operation time Auto start time External integration 1 hour External integration 2 hours date Times of Day Power-on time (unit: motion cycle) Automatic... [read more]
Support | Citizen Mitsubishi Commands | Data on date  time etc

Support | Citizen Mitsubishi Commands | Data on forced output of device

Modal output device 1 Modal output number 1 Modal output data 1 Modal output device 2 Modal output number 2 Modal output data 2 Modal output device 3 Modal output number 3 Modal... [read more]
Support | Citizen Mitsubishi Commands | Data on forced output of device

Support | Citizen Mitsubishi Commands | Data on I F of super option

Data setting completion flag PC command NC status Point balance Used points Purchase point Subtraction point 1 Subtraction point 2 Warning point 1 Warning point 2 See:... [read more]
Support | Citizen Mitsubishi Commands | Data on I  F of super option

Support | Citizen Mitsubishi Commands | Data on M S T B function

M directive S command (1st spindle) S command (second main spindle) S directive (third spindle) S command (fourth main spindle) S command (fifth spindle) S directive (sixth... [read more]
Support | Citizen Mitsubishi Commands | Data on M  S  T  B function

Support | Citizen Mitsubishi Commands | Data on Machine Para Open I F

Machine para opening I / F 1 Machine para opening I / F 2 Machine para opening I / F 3 Machine para opening I / F 4 Machine para opening I / F 5 Machine para opening I / F 6... [read more]
Support | Citizen Mitsubishi Commands | Data on Machine Para Open I  F

Support | Citizen Mitsubishi Commands | Data on machine specification

Stored stroke limit (+) # 2014 OT + Stored stroke limit (-) # 2015 OT- Axis parameter # 8208 Soft limit + Axis parameter # 8204 Soft limit - Rotational axis # 1017 rot Diameter... [read more]
Support | Citizen Mitsubishi Commands | Data on machine specification

Support | Citizen Mitsubishi Commands | Data on memory read write

Memory read / write 1 byte data Memory read / write 2 byte data Memory read / write 4 byte data See: IIoT... [read more]
Support | Citizen Mitsubishi Commands | Data on memory read  write

Support | Citizen Mitsubishi Commands | Data on message notification

Message notification information Message notification busy flag Message notification status Driver processing time Message reception function processing time See:... [read more]
Support | Citizen Mitsubishi Commands | Data on message notification

Support | Citizen Mitsubishi Commands | Data on PLC switch load meter display

PLC switch name PLC switch input signal PLC switch input signal (collective) PLC switch output signal PLC switch output signal (collective) Road meter comment See:... [read more]
Support | Citizen Mitsubishi Commands | Data on PLC switch load meter display

Support | Citizen Mitsubishi Commands | Data on position switch

Axis name 1 Dog position 1-1 Dog position 2-1 Axis name 2 Dog position 1-2 Dog position 2-2 Axis name 3 Dog position 1-3 Dog position 2-3 Axis name 4 Dog position 1-4 Dog... [read more]
Support | Citizen Mitsubishi Commands | Data on position switch

Support | Citizen Mitsubishi Commands | Data on power supply monitor servo axis main axis

Power Supply Quantity Power supply name Unit type name Unit serial number S / W version Connected drive Recovered energy Power-supply voltage PN bus voltage MINPN bus voltage Bus... [read more]
Support | Citizen Mitsubishi Commands | Data on power supply monitor servo axis main axis

Support | Citizen Mitsubishi Commands | Data on program correction I F in program check

Reverse Block Stop Request Buffer correctability information See: IIoT Device Driver for Citizen Mitsubishi... [read more]
Support | Citizen Mitsubishi Commands | Data on program correction I  F in program check

Support | Citizen Mitsubishi Commands | Data on servo axis name position state etc

Number of axes (reset state) Axis state Machine position (double type) Current position (double type) Work coordinate position (double type) Remaining command Origin · Zero... [read more]
Support | Citizen Mitsubishi Commands | Data on servo axis name position state etc

Support | Citizen Mitsubishi Commands | Data on servo monitor servo axis

Number of axes Axis name gain Droop Rotational speed Feed speed Load current MAX current 1 MAX current 2 MAX current 3 Overload Regenerative load Estimated disturbance torque MAX... [read more]
Support | Citizen Mitsubishi Commands | Data on servo monitor servo axis

Support | Citizen Mitsubishi Commands | Data on servo monitor spindle type servo

Number of axes Axis name gain Droop Rotational speed Feed speed Load current MAX current 1 MAX current 2 MAX current 3 Overload Regenerative load Estimated disturbance torque MAX... [read more]
Support | Citizen Mitsubishi Commands | Data on servo monitor spindle type servo

Support | Citizen Mitsubishi Commands | Data on super option

Option bit 1 Option bit 2 Option bit 3 Option bit 4 Option bit 5 Option bit 6 Option bit 7 Option bit 8 Option bit 9 Option bit 10 Option bit 11 Option bit 12 Option bit 13... [read more]
Support | Citizen Mitsubishi Commands | Data on super option

Support | Citizen Mitsubishi Commands | Data on tool life management Lifetime management method I II

Tool life management ?: Time Tool life management ?: Number of times Tool life management ?: Status Tool life management ?: Tool No. Tool life management ?: Status Tool life... [read more]
Support | Citizen Mitsubishi Commands | Data on tool life management Lifetime management method I II

Support | Citizen Mitsubishi Commands | Data on tool offset

Tool correction group number Tool correction amount: Edge wear amount: X Tool correction amount: cutting edge wear amount: Z Tool correction amount: Edge wear amount: Y Tool... [read more]
Support | Citizen Mitsubishi Commands | Data on tool offset

Support | Citizen Mitsubishi Commands | Data on tuning of NC specification

Effective line Inch unit # 1041 I_inch Input unit # 1003 Edit lock B During automatic operation Automatic operation active Machining program tape storage length MACHINE Maker... [read more]
Support | Citizen Mitsubishi Commands | Data on tuning of NC specification

Support | Citizen Mitsubishi Commands | Data on variable

Local Variable Macro Subpro Number of sets of common variable (# 100 ~) Common variable (# 100 ~) Number of sets of common variable (# 500 ~) Common variable (# 500 ~) Custom... [read more]
Support | Citizen Mitsubishi Commands | Data on variable

Support | Citizen Mitsubishi Commands | Data on waveform display screen

Sampling period Sampling type Sampling start trigger signal Sampling start trigger level Sampling data size Waveform display Horizontal scale Sampling data code Sampling data... [read more]
Support | Citizen Mitsubishi Commands | Data on waveform display screen

Support | Citizen Mitsubishi Commands | Data on work offset

G 58 Work coordinate system offset G59 Work coordinate system offset G54 Work coordinate system offset (extension I / F) G55 Work coordinate system offset (extended I / F) G56... [read more]
Support | Citizen Mitsubishi Commands | Data on work offset

Support | Citizen Mitsubishi Commands | Data related to auxiliary axis J2CT control

Number of auxiliary axes Axis valid / invalid information driving Operation adjustment mode Absolute position set Position set state Operation mode Operating parameters... [read more]
Support | Citizen Mitsubishi Commands | Data related to auxiliary axis J2CT control

Support | Citizen Mitsubishi Commands | Data relating to auxiliary axis J2CT monitor

Droop Rotational speed Load current MAX current 1 MAX current 2 Load factor Regenerative load Current station number present location Target station number Command position... [read more]
Support | Citizen Mitsubishi Commands | Data relating to auxiliary axis J2CT monitor

Support | Citizen Mitsubishi Commands | Data relating to spindle monitor including spindle type servo

Number of axes Axis name gain Droop Rotational speed Load MAX current 1 MAX current 2 MAX current 3 Overload Regenerative load Estimated disturbance torque MAX disturbance torque... [read more]
Support | Citizen Mitsubishi Commands | Data relating to spindle monitor including spindle type servo

Support | Citizen Mitsubishi Commands | Data relating to the operating state etc of the spindle

First spindle rotation speed Second spindle rotation speed Third spindle rotation speed Fourth spindle rotation speed Fifth spindle rotation speed Sixth spindle rotation speed... [read more]
Support | Citizen Mitsubishi Commands | Data relating to the operating state etc of the spindle

Support | Citizen Mitsubishi Commands | Event I F

DPRNT function start / end notice DPRNT execution state MelPostMessageEx start notification MelPostMessageEx start end notice MelPostMsgBufferEx start notification... [read more]
Support | Citizen Mitsubishi Commands | Event I  F

Support | Citizen Mitsubishi Commands | Key history data

History function control History data update check Read history data See: IIoT Device Driver for Citizen... [read more]
Support | Citizen Mitsubishi Commands | Key history data

Support | Citizen Mitsubishi Commands | M600L compatible I F for Citizens group

Network option 06 Network option 07 Network option 08 Network option 09 Network option 11 Network option 11 Network option 12 Network option 13 Network options 14 Network option... [read more]
Support | Citizen Mitsubishi Commands | M600L compatible I  F for Citizens group

Support | Citizen Mitsubishi Commands | MELDAS NET failure diagnosis information

Presence / absence of fault diagnosis information See: IIoT Device Driver for Citizen Mitsubishi... [read more]
Support | Citizen Mitsubishi Commands | MELDAS NET failure diagnosis information

Support | Citizen Mitsubishi Commands | MELDAS diagnostic data

Initialization of diagnostic information Check for existence of diagnostic information SRAM maximum size of diagnostic information DRAM maximum size of diagnostic information NC... [read more]
Support | Citizen Mitsubishi Commands | MELDAS diagnostic data

Support | Citizen Mitsubishi Commands | Memory Read Write

See: IIoT Device Driver for Citizen Mitsubishi controllers... [read more]
Support | Citizen Mitsubishi Commands | Memory Read Write

Support | Citizen Mitsubishi Commands | Parameter

G00 dry run Macro single Ignore middle point Machine lock high speed ABS / INC address G04 Time fixed Interference avoidance Command unit 10 times Decimal type 2 G00... [read more]
Support | Citizen Mitsubishi Commands | Parameter

Support | Citizen Mitsubishi Commands | Simulation I F

Mode set Mode reset Forwarding information Interpolation type Coordinate system type Data precision type Data transfer request See:... [read more]
Support | Citizen Mitsubishi Commands | Simulation I  F
Modified: 2024-03-26