O: Program number (main program) N: Sequence number (main program) B: Block number (main program) O: Program number (subprogram) N: Sequence number (subprogram) B: Block number (subprogram) Subprogram

See: Device Driver for Citizen Mitsubishi controllers

CommandDescription
SECT_PRG_MAIN_OO: Program number (main program)
SECT_PRG_MAIN_NN: Sequence number (main program)
SECT_PRG_MAIN_BB: Block number (main program)
SECT_PRG_SUB_OO: Program number (subprogram)
SECT_PRG_SUB_NN: Sequence number (subprogram)
SECT_PRG_SUB_BB: Block number (subprogram)
SECT_PRG_NESTSubprogram call level
SECT_PRG_MAIN_O_DEVSearch completed main program storage destination
SECT_PRG_SUB_O_DEV Search completed subprogram storage location
SECT_G_GROUP1G command value (group 1 command)
SECT_G_GROUP2G command value (Group 2 command)
SECT_G_GROUP3G command value (Group 3 command)
SECT_G_GROUP4G command value (group 4 command)
SECT_G_GROUP5G command value (group 5 command)
SECT_G_GROUP6G command value (group 6 command)
SECT_G_GROUP7G command value (group 7 command)
SECT_G_GROUP8G command value (group 8 command)
SECT_G_GROUP9G command value (group 9 directive)
SECT_G_GROUP10G command value (group 10 command)
SECT_G_GROUP11G command value (group 11 command)
SECT_G_GROUP12G command value (group 12 command)
SECT_G_GROUP13G command value (group 13 command)
SECT_G_GROUP14G command value (group 14 command)
SECT_G_GROUP15G command value (group 15 command)
SECT_G_GROUP16G command value (group 16 command)
SECT_G_GROUP17G command value (group 17 command)
SECT_G_GROUP18G command value (group 18 command)
SECT_G_GROUP19G command value (group 19 directive)
SECT_G_GROUP20G command value (group 20 command)
SECT_G_GROUP21G command value (group 21 command)
SECT_G_GROUP22G command value (group 22 command)
SECT_G_GROUP23G command value (group 23 command)
SECT_G_GROUP24G command value (group 24 command)
SECT_G_GROUP25G command value (group 25 command)
SECT_G_GROUP26G command value (group 26 command)
SECT_G_GROUP27G command value (group 27 directive)
SECT_G_GROUP28G command value (group 28 command)
SECT_G_GROUP29G command value (group 29 command)
SECT_G_GROUP30G command value (group 30 command)
SECT_FAFA: F command feed speed
SECT_FSFS: Synchronous feed speed
SECT_FCFc: Automatic effective feedrate
SECT_FEFE: Screw lead
SECT_DWELLDwell remaining time
SECT_SINGLE_B_STSInvalid state: single block
SECT_MSTFIN_STSInvalid state: MST complete
SECT_FEEDHOLD_STSInvalid state: feed hold
SECT_OVERRIDE_STSInvalid state: Override
SECT_IGSACT_STSInvalid state: Exact
SECT_ACT_MAIN_COMMENTProgram comment
SECT_RUN_STATUSOperating condition
SECT_RUN_MODEOperation mode
SECT_SUB_SYSTEM_INFO1Sub-line information 1
SECT_SUB_SYSTEM_INFO2Sub-line information 2
SECT_CURRENT_PROGRunning program (type 1)
SECT_ALARM_INFO_COMAlarm information (common to the system)
SECT_ALARM_INFO_SYSAlarm information (system independent)
SECT_ACT_REAL_P_NORunning program number
SECT_ACT_REAL_B_NORunning block number
SECT_PLC_MESSAGEPLC message information
SECT_PRG_MAIN_O_MEMO: Search program number of memory operation
SECT_TOOL_COMPENSATION1Tool correction number 1
SECT_TOOL_COMPENSATION2Tool correction number 2
SECT_UPDATE_AXIS_INFOAxis information update counter
SECT_CURRENT_PROG2Running program (type 2)
SECT_CURRENT_PROG3Running program (type 3)
SECT_CURRENT_PROG4Running program (type 4)
SECT_ALARM_CHG_CNTAlarm message update information
SECT_PRG_TREE_OProgram tree information O: Program number
SECT_PRG_TREE_NProgram tree information N: Sequence number
SECT_PRG_TREE_BProgram tree information B: Block number
SECT_PRG_TREE_LProgram tree information L: Loop count
SECT_PRG_TREE_MODEProgram tree information operation mode
SECT_MDI_STATUSMDI setting status

 

Privacy notice

This website uses cookies. By continuing to use it you agree to our privacy policy. 

https://www.inventcom.net/support/citizen-mitsubishi-commands/data-on-current-nc-program-and-running-status

Support | Citizen Mitsubishi Commands | Overview

Here yo can find a list of command sections for Mitsubishi CNC controllers on Citizen and... [read more]
Support | Citizen Mitsubishi Commands | Overview

Support | Citizen Mitsubishi Commands | Axis independent parameter

Axis name Basic Specification Para # 11 abson Absolute position set # 1 SET Absolute position set # 2 base Absolute position set SET_FIN Machine end E - G Axis specification para... [read more]
Support | Citizen Mitsubishi Commands | Axis independent parameter

Support | Citizen Mitsubishi Commands | Axis status

/ * First reference point * / / * 2nd reference point * / / * Third reference point * / / * Fourth reference point * / / * Servo OFF status * / / * In the mirror image * / / *... [read more]
Support | Citizen Mitsubishi Commands | Axis status

Support | Citizen Mitsubishi Commands | Buffer correction

Start buffer correction Buffer correction end Acquire buffer correction status Buffer correction point acquisition (O number) Acquire buffer correction point (block) Buffer... [read more]
Support | Citizen Mitsubishi Commands | Buffer correction

Support | Citizen Mitsubishi Commands | Data on alarm

Absolute value alarm: attribute              : Sub 1              : Sub 2              :number Servo alarm: attribute              : Sub 1              : Sub 2... [read more]
Support | Citizen Mitsubishi Commands | Data on alarm

Support | Citizen Mitsubishi Commands | Data on arbitrary axis superposition

Arbitrary superimposition control data 1 Arbitrary superimposition control data 2 Arbitrary superimposition control data 3 Arbitrary superimposition control data 4 Arbitrary... [read more]
Support | Citizen Mitsubishi Commands | Data on arbitrary axis superposition

Support | Citizen Mitsubishi Commands | Data on date time etc

Power on time Automatic operation time Auto start time External integration 1 hour External integration 2 hours date Times of Day Power-on time (unit: motion cycle) Automatic... [read more]
Support | Citizen Mitsubishi Commands | Data on date  time etc

Support | Citizen Mitsubishi Commands | Data on forced output of device

Modal output device 1 Modal output number 1 Modal output data 1 Modal output device 2 Modal output number 2 Modal output data 2 Modal output device 3 Modal output number 3 Modal... [read more]
Support | Citizen Mitsubishi Commands | Data on forced output of device

Support | Citizen Mitsubishi Commands | Data on I F of super option

Data setting completion flag PC command NC status Point balance Used points Purchase point Subtraction point 1 Subtraction point 2 Warning point 1 Warning point 2 See:... [read more]
Support | Citizen Mitsubishi Commands | Data on I  F of super option

Support | Citizen Mitsubishi Commands | Data on M S T B function

M directive S command (1st spindle) S command (second main spindle) S directive (third spindle) S command (fourth main spindle) S command (fifth spindle) S directive (sixth... [read more]
Support | Citizen Mitsubishi Commands | Data on M  S  T  B function

Support | Citizen Mitsubishi Commands | Data on Machine Para Open I F

Machine para opening I / F 1 Machine para opening I / F 2 Machine para opening I / F 3 Machine para opening I / F 4 Machine para opening I / F 5 Machine para opening I / F 6... [read more]
Support | Citizen Mitsubishi Commands | Data on Machine Para Open I  F

Support | Citizen Mitsubishi Commands | Data on machine specification

Stored stroke limit (+) # 2014 OT + Stored stroke limit (-) # 2015 OT- Axis parameter # 8208 Soft limit + Axis parameter # 8204 Soft limit - Rotational axis # 1017 rot Diameter... [read more]
Support | Citizen Mitsubishi Commands | Data on machine specification

Support | Citizen Mitsubishi Commands | Data on memory read write

Memory read / write 1 byte data Memory read / write 2 byte data Memory read / write 4 byte data See: Device Driver for... [read more]
Support | Citizen Mitsubishi Commands | Data on memory read  write

Support | Citizen Mitsubishi Commands | Data on message notification

Message notification information Message notification busy flag Message notification status Driver processing time Message reception function processing time See:... [read more]
Support | Citizen Mitsubishi Commands | Data on message notification

Support | Citizen Mitsubishi Commands | Data on PLC switch load meter display

PLC switch name PLC switch input signal PLC switch input signal (collective) PLC switch output signal PLC switch output signal (collective) Road meter comment See:... [read more]
Support | Citizen Mitsubishi Commands | Data on PLC switch load meter display

Support | Citizen Mitsubishi Commands | Data on position switch

Axis name 1 Dog position 1-1 Dog position 2-1 Axis name 2 Dog position 1-2 Dog position 2-2 Axis name 3 Dog position 1-3 Dog position 2-3 Axis name 4 Dog position 1-4 Dog... [read more]
Support | Citizen Mitsubishi Commands | Data on position switch

Support | Citizen Mitsubishi Commands | Data on power supply monitor servo axis main axis

Power Supply Quantity Power supply name Unit type name Unit serial number S / W version Connected drive Recovered energy Power-supply voltage PN bus voltage MINPN bus voltage Bus... [read more]
Support | Citizen Mitsubishi Commands | Data on power supply monitor servo axis main axis

Support | Citizen Mitsubishi Commands | Data on program correction I F in program check

Reverse Block Stop Request Buffer correctability information See: Device Driver for Citizen Mitsubishi controllers... [read more]
Support | Citizen Mitsubishi Commands | Data on program correction I  F in program check

Support | Citizen Mitsubishi Commands | Data on servo axis name position state etc

Number of axes (reset state) Axis state Machine position (double type) Current position (double type) Work coordinate position (double type) Remaining command Origin · Zero... [read more]
Support | Citizen Mitsubishi Commands | Data on servo axis name position state etc

Support | Citizen Mitsubishi Commands | Data on servo monitor servo axis

Number of axes Axis name gain Droop Rotational speed Feed speed Load current MAX current 1 MAX current 2 MAX current 3 Overload Regenerative load Estimated disturbance torque MAX... [read more]
Support | Citizen Mitsubishi Commands | Data on servo monitor servo axis

Support | Citizen Mitsubishi Commands | Data on servo monitor spindle type servo

Number of axes Axis name gain Droop Rotational speed Feed speed Load current MAX current 1 MAX current 2 MAX current 3 Overload Regenerative load Estimated disturbance torque MAX... [read more]
Support | Citizen Mitsubishi Commands | Data on servo monitor spindle type servo

Support | Citizen Mitsubishi Commands | Data on super option

Option bit 1 Option bit 2 Option bit 3 Option bit 4 Option bit 5 Option bit 6 Option bit 7 Option bit 8 Option bit 9 Option bit 10 Option bit 11 Option bit 12 Option bit 13... [read more]
Support | Citizen Mitsubishi Commands | Data on super option

Support | Citizen Mitsubishi Commands | Data on tool life management Lifetime management method I II

Tool life management ?: Time Tool life management ?: Number of times Tool life management ?: Status Tool life management ?: Tool No. Tool life management ?: Status Tool life... [read more]
Support | Citizen Mitsubishi Commands | Data on tool life management Lifetime management method I II

Support | Citizen Mitsubishi Commands | Data on tool offset

Tool correction group number Tool correction amount: Edge wear amount: X Tool correction amount: cutting edge wear amount: Z Tool correction amount: Edge wear amount: Y Tool... [read more]
Support | Citizen Mitsubishi Commands | Data on tool offset

Support | Citizen Mitsubishi Commands | Data on tuning of NC specification

Effective line Inch unit # 1041 I_inch Input unit # 1003 Edit lock B During automatic operation Automatic operation active Machining program tape storage length MACHINE Maker... [read more]
Support | Citizen Mitsubishi Commands | Data on tuning of NC specification

Support | Citizen Mitsubishi Commands | Data on variable

Local Variable Macro Subpro Number of sets of common variable (# 100 ~) Common variable (# 100 ~) Number of sets of common variable (# 500 ~) Common variable (# 500 ~) Custom... [read more]
Support | Citizen Mitsubishi Commands | Data on variable

Support | Citizen Mitsubishi Commands | Data on waveform display screen

Sampling period Sampling type Sampling start trigger signal Sampling start trigger level Sampling data size Waveform display Horizontal scale Sampling data code Sampling data... [read more]
Support | Citizen Mitsubishi Commands | Data on waveform display screen

Support | Citizen Mitsubishi Commands | Data on work offset

G 58 Work coordinate system offset G59 Work coordinate system offset G54 Work coordinate system offset (extension I / F) G55 Work coordinate system offset (extended I / F) G56... [read more]
Support | Citizen Mitsubishi Commands | Data on work offset

Support | Citizen Mitsubishi Commands | Data related to auxiliary axis J2CT control

Number of auxiliary axes Axis valid / invalid information driving Operation adjustment mode Absolute position set Position set state Operation mode Operating parameters... [read more]
Support | Citizen Mitsubishi Commands | Data related to auxiliary axis J2CT control

Support | Citizen Mitsubishi Commands | Data relating to auxiliary axis J2CT monitor

Droop Rotational speed Load current MAX current 1 MAX current 2 Load factor Regenerative load Current station number present location Target station number Command position... [read more]
Support | Citizen Mitsubishi Commands | Data relating to auxiliary axis J2CT monitor

Support | Citizen Mitsubishi Commands | Data relating to spindle monitor including spindle type servo

Number of axes Axis name gain Droop Rotational speed Load MAX current 1 MAX current 2 MAX current 3 Overload Regenerative load Estimated disturbance torque MAX disturbance torque... [read more]
Support | Citizen Mitsubishi Commands | Data relating to spindle monitor including spindle type servo

Support | Citizen Mitsubishi Commands | Data relating to the operating state etc of the spindle

First spindle rotation speed Second spindle rotation speed Third spindle rotation speed Fourth spindle rotation speed Fifth spindle rotation speed Sixth spindle rotation speed... [read more]
Support | Citizen Mitsubishi Commands | Data relating to the operating state etc of the spindle

Support | Citizen Mitsubishi Commands | Driving state

See: Device Driver for Citizen Mitsubishi controllers... [read more]
Support | Citizen Mitsubishi Commands | Driving state

Support | Citizen Mitsubishi Commands | Event I F

DPRNT function start / end notice DPRNT execution state MelPostMessageEx start notification MelPostMessageEx start end notice MelPostMsgBufferEx start notification... [read more]
Support | Citizen Mitsubishi Commands | Event I  F

Support | Citizen Mitsubishi Commands | Key history data

History function control History data update check Read history data See: Device Driver for Citizen Mitsubishi... [read more]
Support | Citizen Mitsubishi Commands | Key history data

Support | Citizen Mitsubishi Commands | Local variable screen invalid state macro

/ * Exact * / / * Override * / / * Feed hold * / / * MST completion * / / * Single block * / See: Device Driver for... [read more]
Support | Citizen Mitsubishi Commands | Local variable screen invalid state macro

Support | Citizen Mitsubishi Commands | M600L compatible I F for Citizens group

Network option 06 Network option 07 Network option 08 Network option 09 Network option 11 Network option 11 Network option 12 Network option 13 Network options 14 Network option... [read more]
Support | Citizen Mitsubishi Commands | M600L compatible I  F for Citizens group

Support | Citizen Mitsubishi Commands | MELDAS NET failure diagnosis information

Presence / absence of fault diagnosis information See: Device Driver for Citizen Mitsubishi controllers... [read more]
Support | Citizen Mitsubishi Commands | MELDAS NET failure diagnosis information

Support | Citizen Mitsubishi Commands | MELDAS diagnostic data

Initialization of diagnostic information Check for existence of diagnostic information SRAM maximum size of diagnostic information DRAM maximum size of diagnostic information NC... [read more]
Support | Citizen Mitsubishi Commands | MELDAS diagnostic data

Support | Citizen Mitsubishi Commands | Memory Read Write

See: Device Driver for Citizen Mitsubishi controllers... [read more]
Support | Citizen Mitsubishi Commands | Memory Read Write

Support | Citizen Mitsubishi Commands | NC system information acquired

See: Device Driver for Citizen Mitsubishi controllers... [read more]
Support | Citizen Mitsubishi Commands | NC system information acquired

Support | Citizen Mitsubishi Commands | NC system information setting

APLC token string over APLC token Returned value See: Device Driver for Citizen Mitsubishi... [read more]
Support | Citizen Mitsubishi Commands | NC system information setting

Support | Citizen Mitsubishi Commands | Operation mode

/ * Step mode STP * / / * Fast-forward mode RPD * / / * Automatic Dogless type Home Return AST * / / * Home return ZRN * / See:... [read more]
Support | Citizen Mitsubishi Commands | Operation mode

Support | Citizen Mitsubishi Commands | Option check macro for acquisition

See: Device Driver for Citizen Mitsubishi controllers... [read more]
Support | Citizen Mitsubishi Commands | Option check macro for acquisition

Support | Citizen Mitsubishi Commands | Option check macro for setting

See: Device Driver for Citizen Mitsubishi controllers... [read more]
Support | Citizen Mitsubishi Commands | Option check macro for setting

Support | Citizen Mitsubishi Commands | Parameter

G00 dry run Macro single Ignore middle point Machine lock high speed ABS / INC address G04 Time fixed Interference avoidance Command unit 10 times Decimal type 2 G00... [read more]
Support | Citizen Mitsubishi Commands | Parameter

Support | Citizen Mitsubishi Commands | Parameter access level

See: Device Driver for Citizen Mitsubishi controllers... [read more]
Support | Citizen Mitsubishi Commands | Parameter access level

Support | Citizen Mitsubishi Commands | PLC device

Device B (one shot) link relay Device C (one shot) counter input Device C (one shot) counter output Device E (one shot) special relay Device SM (one shot) special relay Device F... [read more]
Support | Citizen Mitsubishi Commands | PLC device

Support | Citizen Mitsubishi Commands | PLC message information macro

/ * PLC alarm message 1 * / / * PLC alarm message 2 * / / * PLC alarm message 3 * / / * PLC alarm message 4 * / / * PLC operator message * / See:... [read more]
Support | Citizen Mitsubishi Commands | PLC message information macro

Support | Citizen Mitsubishi Commands | Simulation I F

Mode set Mode reset Forwarding information Interpolation type Coordinate system type Data precision type Data transfer request See:... [read more]
Support | Citizen Mitsubishi Commands | Simulation I  F

Support | Citizen Mitsubishi Commands | Sub system information acquisition macro

/ * Sub-line identification number * / / * Sub-line calling system * / / * Sub-line calling information * / / * Wait for sub-system completion * / See:... [read more]
Support | Citizen Mitsubishi Commands | Sub system information acquisition macro

Support | Citizen Mitsubishi Commands | System common alarm information acquisition macro

/ * System alarm * / / * Spindle alarm * / / * MCP alarm * / / * Basic PC alarm * / / * User PC alarm * / / * Spindle warning * / / * MCP warning * / / * System warning * / See:... [read more]
Support | Citizen Mitsubishi Commands | System common alarm information acquisition macro

Support | Citizen Mitsubishi Commands | System independent alarm information acquisition macro

/ * System alarm * / / * Servo alarm * / / * MCP alarm * / / * Program error * / / * System warning * / / * Servo warning * / / * MCP warning * / / * Operation error * / / * Stop... [read more]
Support | Citizen Mitsubishi Commands | System independent alarm information acquisition macro
Modified: 2017-09-02